9(2).99 how many bytes take? Why . consider as a byte?
Answer Posted / guest
5 bytes
| Is This Answer Correct ? | 7 Yes | 2 No |
Post New Answer View All Answers
Mention the guidelines to write a structured cobol program?
What is inspect in cobol ?
I need to compare 3 variables(dates) and do some processing based on the earliest date. There could be more then 1 date record in any of the 3 fields. What is the best way to code this?
IDENTIFICATION DIVISION. PROGRAM-ID. UPDT. AUTHOR.anbu. DATE-WRITTEN. AUG 13. ENVIRONMENT DIVISION. INPUT-OUTPUT SECTION. FILE-CONTROL. SELECT CMSTR ASSIGN TO CINP1 ORGANIZATION IS INDEXED ACCESS IS SEQUENTIAL RECORD KEY CM2-KEY FILE STATUS IS WS-CMSTR-FST. SELECT CTAB ASSIGN TO CINP2 ORGANIZATION IS ACCESS IS SEQUENTIAL RECORD KEY VSAM-WHSE- KEY FILE STATUS IS WS-CTAB- FST. DATA DIVISION. FILE SECTION. FD CMSTR. COPY RXCYFC20. FD CTAB. COPY AITYWHSE. ************************************************************ ****** *** WORKING STORAGE VARIABLES *** ************************************************************ ****** WORKING-STORAGE SECTION. 01 WS- VARIABLES. 05 WS-EB PIC X(02) VALUE ZEROES. 05 WS-DIV PIC 9(03) VALUE ZEROES. 05 WS-CMF-RECS-REWRITTEN PIC 9(01) VALUE ZERO. *** FILE STATUS VARIABLES *** 05 WS- FILESTATUS. 10 WS-CMSTR-FST PIC 9(02) VALUE ZEROES. 10 WS-CTAB-FST PIC 9(02) VALUE ZEROES. *** END OF FILE VARIABLES *** 05 WS-CMSTR-EOF PIC X(01) VALUE 'N'. 88 WS-CMSTR-EOF-YES VALUE 'Y'. 88 WS-CMSTR-EOF-NO VALUE 'N'. 05 WS-CTAB-EOF PIC X(01) VALUE 'N'. 88 WS-CTAB-EOF-YES VALUE 'Y'. 88 WS-CTAB-EOF-NO VALUE 'N'. **** ERROR VARIABLES **** 05 WC-ABEND-900 PIC 9(03) VALUE 900. 05 WE-ERR-CODE PIC 9(02) VALUE ZEROES. 05 WE-ABEND-CODE PIC 9(03) VALUE ZEROES. ************************************************************ **** ********* PROCEDURE DIVISON ********** ************************************************************ **** PROCEDURE DIVISION. 0000- BEGIN. PERFORM 1000-INITIALISE THRU 1000- EXIT. PERFORM 2000-PROCESS THRU 2000- EXIT UNTIL WS-CMSTR-EOF- YES. DISPLAY 'WS-CMF-RECS-REWRITTEN :' WS-CMF-RECS- REWRITTEN. PERFORM 5000-CLOSE THRU 5000- EXIT. GOBACK. 0000- EXIT. EXIT. 1000- INITIALISE. OPEN I-O CMSTR. EVALUATE WS-CMSTR- FST WHEN 00 WHEN 97 CONTINUE WHEN OTHER DISPLAY 'ERROR IN READING INPUT FILE: ' DISPLAY WS-CMSTR-FST MOVE WS-CMSTR-FST TO WE-ERR-CODE PERFORM 9999-ABEND-PARA THRU 9999-EXIT END-EVALUATE. OPEN INPUT CTAB. EVALUATE WS-CTAB-FST WHEN 00 WHEN 97 CONTINUE WHEN OTHER DISPLAY 'ERROR IN READING INPUT FILE: ' DISPLAY WS-CTAB-FST MOVE WS-CTAB-FST TO WE-ERR-CODE PERFORM 9999-ABEND-PARA THRU 9999-EXIT END-EVALUATE. 1000-EXIT. EXIT. 2000-PROCESS. READ CMSTR. EVALUATE WS-CMSTR-FST WHEN 00 CONTINUE WHEN 10 SET WS-CMSTR-EOF-YES TO TRUE GO TO 2000-EXIT WHEN OTHER DISPLAY 'ERROR IN READING INPUT FILE: ' DISPLAY WS-CMSTR-FST MOVE WS-CMSTR-FST TO WE-ERR-CODE PERFORM 9999-ABEND-PARA THRU 9999-EXIT END-EVALUATE IF CM2-RECORD-TYPE-SOLD-TO MOVE CM2-ENTERING-BRANCH TO WS-EB PERFORM 3000-READ THRU 3000-EXIT UNTIL WS-CTAB-EOF-YES END-IF. 2000-EXIT. EXIT. 3000-READ. MOVE WS-EB TO VSAM-WHSE-CD. MOVE 'WHSE' TO VSAM-WHSE-ID. READ CTAB. EVALUATE WS-CTAB-FST WHEN 00 MOVE WHSE-DIV-CODE TO WS-DIV PERFORM 4000-REWRITE-CMF THRU 4000-EXIT WHEN 10 SET WS-CTAB-EOF-YES TO TRUE GO TO 3000-EXIT WHEN OTHER DISPLAY 'ERROR IN READING TABLE FILE: ' DISPLAY WS-CTAB-FST MOVE WS-CTAB-FST TO WE-ERR-CODE PERFORM 9999-ABEND-PARA THRU 9999-EXIT END- EVALUATE. 3000- EXIT. EXIT. 4000-REWRITE- CMF. IF WS-DIV = 250 OR 252 MOVE 'F' TO CM2-FREIGHT- TYPE MOVE 1 TO CM2-FREIGHT-THRESHOLD- AMT ADD +1 TO WS-CMF-RECS- REWRITTEN REWRITE CM2-SOLD-TO- RECORD DISPLAY 'RECORD UPDATED' END- IF. * EVALUATE WS-CMSTR- FST * WHEN 00 * CONTINUE * WHEN OTHER * DISPLAY 'FILE NOT UPDATED' * DISPLAY WS-CMSTR- FST * MOVE WS-CMSTR-FST TO WE-ERR-CODE * PERFORM 9999-ABEND-PARA THRU 9999-EXIT * GO TO 4000-EXIT * END-EVALUATE. 4000-EXIT. EXIT. 5000-CLOSE. CLOSE CMSTR CTAB. 5000-EXIT. EXIT. 9999-ABEND-PARA. COMPUTE WE-ABEND-CODE = WC-ABEND-900 + WE-ERR-CODE CALL 'ILBOABN0' USING WE-ABEND-CODE GO TO 5000-CLOSE. 9999-EXIT. EXIT. 5000-CLOSE. CLOSE CMSTR CTAB. 5000-EXIT. EXIT. 9999-ABEND-PARA. COMPUTE WE-ABEND-CODE = WC-ABEND-900 + WE-ERR-CODE CALL 'ILBOABN0' USING WE-ABEND-CODE GO TO 5000-CLOSE. 9999-EXIT. EXIT. //this program is giving maxcc=0, but not updating..
What is amode(24), amode(31), rmode(24) and rmode(any) (applicable to only mvsesa enterprise server) ?
What is the local-storage section?
How to print 10 to 1 if the input have only 10 digit number?
) How do u handle errors in BMS macro
i was faced one question- i have value -00001234.56 Suppress the zeroes and the output should be -1234.56 But Not - 1234.56 spaces should not be available after suppressing the zeroes. logic in jcl and cobol?
What the difference is between continue and next sentence?
What is the utilization of copybook in cobol? Could we utilize a similar copybook?
How do get the result of your program directly on your pc?
What are literals?
input 1 input2 ouput1 output2 output 3 1 re 300 1 re 200 1 re 300 3 rc 500 1 re 200 2 rr 400 1 re 300 2 rr 400 1 rc 400 3 rc 500 1 rc 400 2 rr 700 2 rr 700 5 tt 900 5 tt 900 2 inputs r in flat file and output 1 is matched records,ouptput2 is unmatched of input1,output3 is unmatched of input2! how vl u get the output files using sequential order and to check with each and every records! let me know the procedure division ?
What is the utilization of copybook in cobol?