Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How would you supply a single house hold load from a 3-phase
supply coming out of a sub-station?

Answer Posted / gopal manda

for only a single house hold load we dont establish three
phase sub station,we establish sigle phase transformer
(5kva,10kva) according to load.for the primary input we
input phase voltage 6.6 kv,one terminal of primary connect
to 11kv phase and other is grounded which is neutral.and we
get 230 volt at secondary.

Is This Answer Correct ?    0 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What should be setting for alarm,tripping and cooling fan on for power transformer's oil temp. and winding temp. indicator?

1904


what is the preventive maintence for ht panels and busbars and vcb abd acb's.

2308


why ct ,cvt should be stored in a vertical position?

2597


What are the advantages of a three-phase system over a single-phase system?

1062


I am having a 42KW 3 phase electrical heating furnace, heating element is 80/20 nichrome material, my connections is made in such a way that 2 star connection compromising 2 coils per phase so totally 12 coils, shall if i use it unbalanced star condition (instead of 2 group of 3 phase or 1 group of 3 phase, connecting 4 phases of 5 phases) what will be the consequences and is it acceptable?

1635


what is v/f control in VFD?

1487


what is strip power factor?

2113


what about GD square and its important for motor design?

3767


how to calculation increase power factor for single phase

2254


can any one provide me a connection wiring diagram for a DG set control panel along with BOM?

2155


What is the most important precaution in any experiment with d.c. Shunt motor?

1207


What is the unit of attenuation?

1012


sent to a site and asked to explain how you would like a twenty seven flour building should be supplied with lighting and sockets plus a water boiler.

1892


why co incidence factor considered in transformer sizing?

1809


suri transmission

4698