Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is meant by damper winding ?

Answer Posted / janani venkatesan

Most of the alternators have thir pole shoes slotted to
receive copper bars of a grid or damper windings.Copper
bars are short circuited at both ends by heavy copper
rings.These DAMPERS are useful in preventing hunting(speed
fluctuations) in generators and are needed in synchronous
motors to provide starting torque.Under normal running
conditions, damper windings does not carry any current
because rotor runs at synchronous speed.They tend to
maintain balanced 3phase voltage under unbalanced load
conditions.

Is This Answer Correct ?    24 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is the preventive maintence for ht panels and busbars and vcb abd acb's.

2384


How to convert a two phase power into a three phase power in induction machine?

1818


How to connect the chemical earthing and complete process tell me plz

1869


whate is the meaning of balance/unbalance,in stabilizers type

2140


A double circuit with dog conductor 66KV Transmission line from wind farm evacuation to feeding substation having capacity of 25MW for transmission. Can same transmission network be considered for further expansion of Power & how much in MW. If we need to expand next 10-15 MW more will there any augmentation is required in transmission network? Kindly reply asap.

2202


I have a current transformer with 1 main reading meter with transformer outside the building and a control panel having 5 CT reading meters with black round coils inside the building. I want to know, A) when current pass through the Transformers, will the current be reduced or be the same and after that B) when current pass through the CT meters with black round coils, will the current be reduced or be the same. C) in the above process will the reading of the main meter be same or different, from the total reading of all the 5 CT meters.

1825


What is the capacity of the Fastners 12mm?

2449


Explain the construction of the conservator, operation and purpose, and draw the diagram of the conservator.

2516


What should be the Sandwitch type Al. bus bar capacity for 2 M.W.Gen. set, having continuous full load current- 3463 Amps,ambient temp.- 50 Deg. C., Required temp. raise-20 deg.C., it will run 24 hrs, 365 days on full load, required highly reliable.

2687


Write the programming software name for LG, SIEMENS,Messung,AB

2043


salam&hi, i need to know about how can i calculate an enough current for the new building before i submit it to the suppliers

2095


HOW DO YOU CAN CHECK A 15KV DIODE, WHETHER IT IS OK OR NOT?

2055


Can we convert off line transformer to on line transformer

1986


Why the arms of delta in a delta-wye power transmission system are kept constant??

1877


Why do not we prefer non conventional sources of energy to conventional sources?