how we can calibrate level transmiiter in field?

Answer Posted / chhote lal

it is a theortical calibration which done before mounted
Level Transmeter in the tank
suppose tank hieght is 10 meters
10 meter = 1000 cm
1000 cm = 10000mmwc
we know that 10000mmwc = 1kg/cm2
so we calibrate Level Transmitter 4mA at 0 kg/cm2(Air
Pressure)
and 20mA at 1kg/cm2 (Air pressure)
thus we calibrate Level transmitter

Is This Answer Correct ?    12 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How can we test a bently nevda 3500/42M accelerometer monitor card by simulating it with test equipment?. what king od of signal (milli volts or volts or or resistance ) we should feed in the terminals of the card?

2028


hi! i want to know about mpse exam.

1796


why we are using drum level control valve air to close?

1618


What is force balance principle? State some of its’ advantages.

722


How d.p. Transmitter can be applied to close tank?

617






Dear Sir/Madam,im going to attend Hpcl written exams on feb 17th in instrumentation stream..can anyone send me the HPCL model papers and pattern of HPCL ....i ve not yet attended anything in HPCL...so i dont know how it comes...so just i need some model test papers and pattern ..pls help me friends...

1644


CONTROL VALVE OPERATING IN MANUAL BUT NOT IN MANUAL. WHAT SHOULD BE THE PROBLEM ?

1470


how can i calibrate the temperatuture gauge used by temperature bath(dry block) i mean step by step procedure?

1237


flow transmitter formula?

2369


Why is the orifice tab provided?

717


Calibration procedure for electro magnetic flow meter

1548


A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.

1703


PLEASE PROVIDE SAMPLES OF CHEVRON SKILL TESTS

3473


what is insdustrial vibration.who it works. give atleast 2 types of insdustrial vibration

1573


The Design Calculation of Level Transmitter For Different Structure open & Closed Vessel, Eg. Diff. Level Tx., Capacitance For Continous Operation

2348