Answer Posted / shoaib9786
Star Connection:
1. It is a setup where in one end of each phase is
connected together so as to form a neutral.
2. It is used for variable loadings
3. The line current = Phase current
4. The Line voltage = sqrt(3)* Phase volatge.
DELTA CONNECTION:
1. It is a setup wherein one end of one phase is joined to
starting end of another end so a ring is completed.
2. It is used for balanced loads.
3. There is no neutral in here
4. Line current = sqrt(3)*phase current
5. Line voltage = phase voltage.
Hope that answers
| Is This Answer Correct ? | 8 Yes | 0 No |
Post New Answer View All Answers
what do you mean by every IC 74 first digit.why are you using this no.why not using another no.
how to find ratio of CT & PT in 66/11kv 12 mva supply system ? explain with calculation.
What are the insulation standerds for eg H clase and how many insulation standerds are there and its standerds??????
Battery is a voltage source? give one example of current source and why?
What is an alternator impedance value?
what is the formula for efficiency of francis turbine and generator for hydropower? what is best way to select francis turbine and generator?
Pleae send me last 5 years of Question book about RRB chennai.
What is the effect on power factor, shown by a trivector meter; incase of reverse phase sequence. If the power factor of a system is lag what meter will show in case of reverse phase sequence connected to the meter. and What in case of lead.
i will applied in 1U-1W on 440 volt primary delta side. what is the result of magtic balance test
I have 4 DG set with 1500KVA rating. system breakers are 11KV & alternator are 415 Volts. Between alternator & breaker one stepup transformer used. i want to Know what is max. resistance for body earthing & 415 & 11KV V Neuteal earthing. my fault current is 14 times for 2 sec.
Advantages/Disadvantages of earthing of neutral bus on MSB instead of separate neutral earthing for transformer/DG sets feeding to MSB
how we start 40w tube light with 4 diodes,2capacitors,1 choke and without starter.(a product avilable in market which lights burnt tube lights also)
We have two APFC panels in same station. I need how to connect CT in two APFC panels.can we take one CT in series connection or two separate CTs.
The knee point of a current transformer is normally unique and known.So why in the nameplate of a CT they put the minimum value like this Vk> 400v.
Why synchronous motor is used in power factor improvement,dc series in lift