Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Which one is correct mVA or MVA. Whether both the units are
same for the transformer

Answer Posted / sudheer_kr

MVA is the correct representation
both units r not d same
MVA refers to Mega volt ampere whereas mVA refers to milli
volt ampere

Is This Answer Correct ?    8 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to select, design,size & calculate for 11 KV/33KV/66KV/132KV/220 KV/440 KV circuit breaker for HT side of transformer protection/HT distribution protection?

2810


What is Long rod insulator and it's applications..? merits over the disc insulator ..?

1974


What are the various types of rotor used in the alternators?

1118


trasnfarmaer core make

2013


why we are not giving the zone 1 trip command to the master trip relay

1795


which one is more efficient, torq, power & ecnomy with the same frame size AC motor / DC motor?

2233


write encoder 17 pins details? pin a;b+, pin b;w+,..pin s & t. what is the meaning of b+, w+? explain;

2197


What is meant by earthhing of a magnetic flow meter and when to use empty pipe detection?

2297


what is the purpose of shading ring or shading coil in electrical equipments.

4535


how to copy from plc ge fanuc versamax series,all input and output, adress, and printout.

2547


How time response of the system is divided?

1233


I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?

2037


If 24 KVA AVR having Input voltage 200-400v, Output voltage 415+-1%, what will be the voltage if Load is 13A.

2136


Proviiding the Dedicated N earth and individual Body Earths ,Finally these all looped /Now my Question :- will it not harm in case of Transformer Fault current flows in Dediacted N Earthing to Looped Body Earthing.

2256


typically in power distribution substation. 1- Any idea how would be the graph of capacitor bank consumption verses time through the day . 2- How is the switching ( on and off ) of the capacitor bank, per need?

1779