what is the static device rather than xmer which work on
same principle as xmer?
Answer Posted / amit. thapar
tubelight choke
| Is This Answer Correct ? | 1 Yes | 4 No |
Post New Answer View All Answers
if a 3phase 100kva distribution transformer , 400 v,50 hz, 4-wire system is loaded at 160 k.w mostly 1-phase Lighting & Airconditioning split a.c load what will be the net effect on the power system in terms of voltage, powerfactor, current , efficiency of xformer
How to measure current and voltage in an ELV circuit
What is the limitation of kirchoffs law?
What is the Diff. btw Manule Pull Station & Manule Abort Station Switches used in FM200 System??
sometime battery charged and then automatically charged when rectifier ON conition, is there any chances please clarify the same.
How to calculate energy stored in an inductance?
List the disadvantages of constant k filters?
tell me about eletrical contractor
how hydrogen cooled alternator undergo maintanence ? that is hydrogen when come in contact with air can result into explosions .
Where is the best place to mount distribution panel in a house.
What is the drawback of class b amplifier? How is this minimized?
how to calulate short circuit current for the following: 1.cable connecting 11KV of 22KV/11KV transformer to 11Kv of 11KV/415V transformer 2.what cable size should i use.
How to work definite,over pluxing,revers power,OSR relay
Why Water motor is not taking a load or pressure while everything is correct. (Note: Motor running properly)
1. A 380 / 220 V r.m.s. 3-phase 4-wire circuit carries loads of 8 + j8.1 ohm; 4 + j4.1 ohm; and 2 +j2.1 ohmin the three phases respectively. The length of the circuit is 100 m, and the resistivity of the phase conductors is 0.0005 Ω/m. The neutral conductor is of the same size as the phase conductors. a) Select a reference angle 0for the first phase. Then write down the three phase voltages in both polar format and complex number format. b) Make appropriate assumptions, and take temperature effects on resistance is insignificant. Calculate the currents in the three phases. (Note: Determine conductor resistance, and apply Kirchhoff’s Voltage Law) Based on the result, suggest a main switch rating for the circuit. c) Show your preferred direction of neutral current in a diagram, and then determine its value. (Note: Apply superposition principle, and Kirchhoff’s Current Law) Use its magnitude to show that in this circuit, the unbalanced load may increase the voltage drop in some of the phases. (Note: Also observe the common volt drip in neutral) State your assumptions, if there are any. d) Suddenly the neutral wire of the circuit is broken. Estimate the new currents in the first phase, i.e. Phase L1. State your assumptions, if there are any.