i want know about capillary type LT transmitter installation. we
can install any location in between to HP and LP leg?
Answer Posted / anish kumaran.r
U should install dpt below the HP side ..Also u can mount anywhere wit some changes in dpt settings,but tat wil not b good one may be errotic
| Is This Answer Correct ? | 2 Yes | 6 No |
Post New Answer View All Answers
key phaser where is use and work
How to decrease opening & closing time of on/off valve?
whats the abbreviation of IOP? is it instrument of power or input open problem?
i have used level transmitter in starch cooking preparation tank. tank total height 2mtr.sometime LT display shows some error value when tank is fully empty and diaphragm side i already checked okay no problem in diaphragm area. field cable checked 24volt and mA shows correct value while tank empty mA is 4mA. 4mA i needed that 0% but display showing 10% or 15% percentage values are varying continously please give any good solution for me.....
what diffrence b/w plc s7200,300,400
why direct mounted pressure transmitters is always installed with DBB ( double bleed block) valve in process line or top of the tanks ?
Type of level transmitter commnly used in Procees area are the following. a.________________This type of level transmitter works as follows
Can Any body tell me about the Contact or Email id of any good Consultancy which help me to find a job in Instrumentation Field in India .I have Six years of Work Experience in the Same field.Please revert me back on shammi_gwalior@yahoo.com ?
Emergency Shutdown Systems/ Plant Shutdown System.
How r the calculation of process line mpm.
Which type of pressure can be measured by primary elements?
plz send me general of ongc
Q1: Consider part of a control loop, which excludes the transmitter, consisting of a process, a controller and a control valve which may be represented by two dead times of 0.5 min each and three exponential lags of 0.8 min., 1.0 min. and 1.5 min. respectively. We wish to express this system as an overall first order plus dead time (FOPLD) model ie gain, time constant and process dead time. (We will see later that this is often done, to simplify controller tuning). For this exercise, gain is considered to be 1.0. (A) If the transmitter is a flow transmitter whose behaviour can be described by a dead time of 0.2 min. and an exponential lag of 0.5 min. in terms of the overall dead time and overall first order lag how can the system behaviour be approximated ? Overall dead time = Overall time constant = (B) If the transmitter is a temperature transmitter with a temperature sensor in a protecting well whose behaviour can be described by a dead time of 0.7 min. and an exponential lag of 15 min. how can the overall system behaviour be approximated now? Overall dead time = Overall time constant =
what about your moleg in pogrees with company
How to Calibrate Level Switch in field