Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

difference between ac motor and dc motor

Answer Posted / hiren barot

Direct current or DC electric motors work for situations
where speed needs to be controlled. DC motors have a stable
and continuous current. DC motors were the first and
earliest motors used. They were found, however, to not be
as good at producing power over long lengths. Electric
companies found using DC motors to generate electric did
not work because the power was lost as the electric was
transmitted. Brush DC motors use rings that conduct the
current and form the magnetic drive that powers the rotor.
Brushless DC motors use a switch to produce the magnetic
drive that powers the rotor. Direct current motors are
often found in appliances around the home.
Alternating current or AC electric motors are used
differently based on what type of AC motor it is. Single
phase AC motors are known as general purpose motors. They
work well in many different situations. These AC motors
work great for systems that are hard to start because they
need a lot of power up front. Three phase, also called
polyphase, AC motors are usually found in industrial
settings. These motors also have high starting power built
transmit lower levels of overall power. AC power gets its
name from the fact that it alternates in power. The amount
of power given off by an AC motor is determined by the
amount of power needed to operate the system

Is This Answer Correct ?    19 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

some time we open engine breaker 8.0 MW load but plant not trip. and another time engine open 4.0 MW load engine trip why? individually engine breaker open & individually emergency stop why difference?

1751


Is a direct shorth ciruit on a branch MCCB in a Low Voltage Switchboard a correct means of tesing the performance for discrimination?

2329


what will happen if ac and dc supplies given

2125


explain the types of drives

1967


Why we find the sensitivity for the CT's to check?

1853


how to set relay setting? and example calculation...

2033


how can we change the phase angle b/w two phase?

5165


I have c license but I don't know eligibility of Max Kilo Volts under the electrical licensing board.

1688


Role of active and reactive Power sharing in between two synchronized Generators, Droop Setting role ?

1755


How Load Factor, Demand Factor, Diversity Factor etc best applied in designing an electrical circuit? Is it allowed to consider these factors in each and every panel in an electrical distribution system? Can any body suggest a good book for reference?

2888


how to interlock 3 nos MCCBs using under voltage coil. please provide me circuit diagram?

2602


what should be the ideal gauge of wire (In sq mm) for different loads in Ampere?

1436


How will you utilise electrical power? You can start from the generating station.

1909


We are designer please help me calculate the size of 11kv cables from step up transformer to M.V panel, total load is 5 mega watt distance 900 feet (used aluminum type cables) please provided formula for calculate the cable with example.

1647


what is ground fault in ACB?

2075