what is the difference between self excited & seperately
excited ?
Answer Posted / g.kiran kumar
for seperatly execited machines an external d.c source is
required to exicte the field coils to emmit the flux.where
in case of self exicted an induced emf induced by the
armature is supply to the field coils.(THERE MUST EXIST
RESIDUEL FLUX IS PRESENT IN FIELD WINDINGS FOR SELF EXICTED
MACHINES)
| Is This Answer Correct ? | 7 Yes | 1 No |
Post New Answer View All Answers
what is mean by transition resistance of transformer?
What is the need of earthing transformer for delta side of a transformer. (Think of a line section between a star/delta transformer at a grid substation and delta/star transformer at a village. An earthing transformer is there at the delta side of the star/delta transformer at grid substation). As there are no ground reference there will not be fault current if a one phase is grounded. Further L-L phase will be sensed by the primary side of star/delta transformer as a L-G fault. So why an earthing transformer is required at delta side
This is reqd for a 1MW Solar power plant..We have 2DC outputs from the solar panels Connected to 2INVERTOR panels.. Output from invertor is 3ph,280v,500kva,50hz.These are connected to individual ACB.This has to be stepped up to 11KV ,1250KVA SYSTEM.Now can I use (1) one more ACBTO GIVE A COMBINED OUTPUT OF 1000KVA,280V & STEP UP THE OUTPUT BY USING a single two winding 3 ph transformer 11kv/1250kva. or (2)use the two outputs and connect to one three winding transformer of above rating..Pls suggestwith details.
What is genrally the % Impedance of a Dg set? How can we calculate Earthing conductor size for a DG set?
Which motor is 3.3 or 11kV more reliable, in terms of efficeancy,maintenance, reliability.
How to Calculate The Neutral Earth flat design calculation for the Synchronised generator (Gen 1-650Kva, Gen 2-725Kva
why in an industry; machine having rated 200 h.p stopped after power factor is maintained above 0.97 lag by control panel in view-of energy saving
What will be result if we connect LT votage to the terminal of HT motor?
How many lightning arrestors to be installed on 50MX60MX10M building and is there any formular for that?
what clearance required for 4.5 mva dry type transformer?
where rlc series ckt used?
What fomula is used to calculate: 1. rated frequency withstand voltage, and 2. rated lightning impulse withstand voltage.
what is the transformer rush current?
what is the difference between the characteristics of two different phase bushing of any transformer