Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

HOW TO FIND OUT 1. LINE CURRENT, 2. PHASE CURRENT IN AN
ALTERNATOR / TRANSFORMER WHICH IS FEEDING A I)STAR LOAD ii)
DELTA LOAD, USING A CLAMP METER.

NORMALLY WHEN WE USE CLAMP METER IN A DG SET THEN WHAT DO
WE GET?? PHASE CURRENT OR LINE CURRENT.

Answer Posted / vivek

I WOULD LIKE TO CLARIFY THE DOUBTS OF MR ANANDHARAJ'S
COMMENTS IN ANSWER 8.. HE FAILED TO UNDERSTAND THE BASICS
OF ELECTRICITY THAT CURRENT ALWAYS FLOW IN A CLOSED LOOP SO
THERE IS NO QUESTION OF OPENING THE LOOP ...AND MOREOVER
WHEN USING CLAMP METER, YOU DONT NEED TO OPEN A CIRCUIT...
SO WHAT I MEANT BY "OPENING" IN ANSWER NO 2 WAS OPENING THE
ENCLOSURE OF THE SOURCE OR THE LOAD IN ORDER TO ACCESS THE
JUNCTION... I HOPE NOW MR ANANDHARAJ WOULD BE IN A BETTER
POSITION TO APPLY HIS RICH EXPERIENCE AND GUIDE A NOVICE
LIKE ME TO GAIN SOME PRACTICAL KNOWLEDGE.. THANKS FOR YOUR
INTEREST.

Is This Answer Correct ?    2 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how to select correct size of power cable for inverter duty motor

1502


which types of relay used in acb and vcb?

2679


How earthing/grounding done in aeroplanes and ships.

3560


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2094


what is acceptance test in electrical engineering.

2103


What is CVT and what is relation with wave trap?

2103


what is the use of surge suppresser in 33 KV incoming panel. where it must be installed,inseries with incoming cable surge suppresser must be at incoming of the breaker are outgoing of the breaker

5322


How to calculate earth wire load by formula

2511


what is the difference between earthing and unearth

2956


What are the advantages of hydropower?

1030


Safety of on line ups

1889


We have 250 KW x 2 motors, which are load from 25% to 100% varying load in every minute , so how can we compansate the power factor. pl give your opinions on the above subject.

1818


What is the meaning of floating point earthing in battery backed systems ?

1957


what are the reasons of CT circuit faulty in busbar protection scheme?

1417


How many sprinklers should be in one pipe line?

1899