Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is Ten Delta Test ?

Answer Posted / kunal

ten delta is measurment of loss angle measured( during
testing for transformer oil) in terms of power factor

Is This Answer Correct ?    3 Yes 8 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is meant by skew width in machines?

2215


what is your majour contributions in your present job

1837


3 phase Motor will be given 2 phase after 2 to 5 second we given 3rd phase so Motor Run sum-time in forward or sum time run reverse direction. All time phase sequence is not change. Why motor run in reverse direction? Please Explain........

1965


I want formula to calculate cable size as per load given in length & amp. I searched many sites but didn't right answer. Please reply me asap.

1472


how to Select its CORE in electrical cables based on its applications? or Application of various types of electrical cable based on it CORE?

3259


The moisture in air will condense at

1184


What is the end effect of linear induction motor ??

2029


what things to be considered when designing UPS

1778


State and define ohm’s law?

1150


how to select size of hardware for linking aluminium busbar is it depend on area of busbar or current flowing through bus bar

2022


describe the Tranformer testing procedure

1883


we have 2.2kw,Y,3000rpm motor but 6leads found in TB what happen if we connect in delta?

1924


Earth leakage relay basic knowledge principle

2186


What is acsr cable and where we use it?

1158


We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?

2151