Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what will happen ac motor give to dc supply

Answer Posted / sehgal

AC motor works on the principle of induction..
The windings in the ac machine are wound either is delta or
star wound. ( ac machine windings )
Only if there is a rotating magnetic field we have an emf
being induced and hence the current.
So only when these current carrying conductors are placed in
the magnetic field, there is a torque!

So if we give a dc supply.. no emf hence no current and
hence no motion! Its in stand still position!

Is This Answer Correct ?    3 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

I have a small system with two motors that are running on 380 vac, 60 hz. These motors are expensive and I usally get them from Brazil. I am adding another motor to the system, but I want to purchase a 480 vac, 60 hz motor to use. It will be on a VFD that is rated fro 380 thru 480. Is this posible and will I have to use a larger motor and derate it?

1959


how to conduct dc resistance test for rotor of an alternator and how to measure the rotor dc resistance value theoritically?

3270


Whar is the KvA rating of 33Kv substation & actual kv rating of power generaating station.

2388


Inductor and capacitor........power in one phase and ...... in it another phase.

2140


What do you mean by a phase angel of instrument transformer?

1102


Explain the difference between verilog task and verilog function?

1325


WHAT IS SHORT CIRCUIT STRENGTH OF 100 AMPS MCCB?

2113


for 4 MVA , 33K.V/6.6K.V transformer. secondary side the connected load is 3000H.P. What is the rating of capacitor bank to be insttaled.

2571


What Should be the value of Vector Surge angle at Tripping and how to calculate it?

2045


Sir, I m 3rd year student 4m DCE and want to do internship in siemens or l&t or any other mnc related to electrical engineering. please tell me the procedure 4 same and oblige me

1966


is it true there's a big difference in using Cummins or Denyo...especially power output or leakage

1928


why transformer ratings in kva? & DG ratings in kva? & Motor ratings in kw/HP?

1501


how to calculate the earth fault current

2498


how to calculate the formula of cable size if motor kw is given

2258


Can any one know what are the symbols at the down (below) the analog ammeter??? there are 4 symbols which are they ?????

1900