Answer Posted / sangeetha.np
The wti is the winding temperature indicator.this is
because the winndings get heated continously, so when it
goes beyond the limit,it has to be indicated tats wat we go
for wti.
| Is This Answer Correct ? | 13 Yes | 27 No |
Post New Answer View All Answers
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
how many joint can done in HT line and what is life of the joint
what is the criteria for selecting fuse rating in 1phase, 2phase & 3phase welding sets?
Which device of PlC does share load between DG sets when DG are running in perallel?
relation between power station capacity and voltage level?
sir,in our plant we r using SATEC PM172E power reading meeters in HT panel side it is monitoring the MB data smart viewer(sever).but last one week we did not get readings inthe server only available in meeter.tell me how communicate meter and server. and also what steps we take for checking.
how you configure motorvision relay (L&T make)from DCS
Why does increasing the magnetic flux in the main field of a d.c motor cause the armature current to reduce??
A double circuit with dog conductor 66KV Transmission line from wind farm evacuation to feeding substation having capacity of 25MW for transmission. Can same transmission network be considered for further expansion of Power & how much in MW. If we need to expand next 10-15 MW more will there any augmentation is required in transmission network? Kindly reply asap.
i am going to attaned the engineer (disign)iterview at HAL please give me duid line
How phase displacement change in the over current relay coils.
What are the no-load losses for the 11000/415V transformer with the following rated capacity? 1.1500 kVA 2. 2000 kVA 3. 2500 kVA 4. 3000 kVA
Thermal withstand capability under full short circuit conditions, in terms of number of times of occurrence of short circuit and corresponding anticipated percentage reduction in transformer life.
surge tank, hrc fuse, earthing transformer, firm power objective type
How to connect the chemical earthing and complete process tell me plz