Answer Posted / waqas haider
many people have written here that current is a vector
because we are to point out its direction. but it is not a
solid defend coz original or electronic current is always
from -ve to +ve terminal so it is not necessary to point
out direction.than how one rely on this defend.. sometimes
we are to point put that light is coming from right
direction to left direction... than will light be a vector?
no.. so give some solid defend.....
| Is This Answer Correct ? | 5 Yes | 5 No |
Post New Answer View All Answers
How to calculate capacitor bank size at a load 800kVA.
my UPS suddenly goes off and all panel light also blow off.This happens even main electric supply is not interrupted.After some time it automatically starts functioning normally.Batteries are new.
how to Select Lighting arrester? What r the parameters to be considered for the selection of Lighting arrester ?
Please send 110 kv sb station full single line drawing(sld)
Starting current of a 10 HP induction Motor is ______ time’s full load current.
Explain the iniluencc of short circuit ratio on the pert'orniancc of synchronous machine.
What if high voltage side circuit breaker of a ehv transformer instead of lvcb? Kindly elaborate.
How can we calculate the KVA rating of a Distribution transformer from its core details?
How to do maintenance of transformer feeder.
In Generator How suction compression power and exhaust works ?
I am completed DEEE in tamilnadu, now i am working in andhrapradesh with 2.5 year experience in relavent field. capacity of the tranformer is 11KV, 1MVA Transformer, i am eligible for getting c licence in andhrapradesh pl help me.
what is the working principle of energy saver control panel. please give the complete calculation & theory.
A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.
what is the difference between switchgear and circuit breakers and is there any difference between outdoor and indoor switchgear and circuit breakers , and how would you differentiate between switch yard and substation and grid station . thanks
what will happen if multimeter(selector switch at DC voltage) and terminal at current is connected to DC supply?