Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is ups?how its works?and what is there in static
switch how it works?

Answer Posted / sakkaravarthi soganur

ups means un interuptible powersupply

ac voltage converted to dc voltage through converter
dc supply connected to baterry also connected to inverter
incoming so we convert dc to ac through inverter.whenever
normal supply failure at that time battry suplly used
without any interuption,
static switch means two scr's connected to antiparallel,and
also this is electronics switch,

Is This Answer Correct ?    2 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

testing of Vector Group – YNaoD II

2938


What is VSCF windelectrical system?

1905


What is the efficiency during maximum power transfer?

1238


in a solar power plant,we are going to step up the voltage 350V to 33kv, and to 132kv GSS. i want to ask that if it is possible that 315v/33kv is not possible because we also use 315v/11kv. or it should be 415v/33kv? is it effects generation or losses?  the second question is-generation is depends on LV winding? or LV winding design for generation voltage?

1742


Readings of ER300P Trivector meter

6425


define digital electronic

1991


What is the difference between a verilog task and a verilog function?

1274


What is the function of under voltage release ?

1430


WHY DO VOLTAGE TRANSFORMERS FAIL DURING EARTH FAULT IN THE DELTA CONNECTED 6.6KV ELECTRICAL SYSTEM

1996


What are locations arc protection relay is fixed.

1883


what reason of line current and phase current in star connection and line current and phase current not equal in delta connection?

2093


what is the stear deltaprinceple?

1884


how to calculate the mesh earth network resistance in such substation, is there any recommended resistance values with references , thanks!

2340


How to calculate the fuse rating depend upon the DC circuit?

2864


for 100 HP Induction motor service factor is 1.2(SF) we placed a VFD at the motor side load is balance with 0.3 Amp's Phase to Phase but at incoming of VFD load is un-balance with 10 to 20 Amp's what will be cause of load un balance

1947