Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what will happen if we give a dc supply to a transformer.?

Answer Posted / sajid

During the time of switching flux links with primary and secondary of the Transformer voltage induced in primary and secondary after that no voltage induced in primary and secondary. Transformer primary take a large current due to the no back emf. This will damage the transformer Primary and later on secondary
Note - If any Correction please send email
msajid1980yahoo.com

Is This Answer Correct ?    3 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

distribution transformer de-rating formula on over limit iron losses  

2298


block diagram of 2 ups system connected in hot stand by mode?

8052


How to calculate the sag of OPGW during stringing???

2572


I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?

1869


In the ACB breaker capacity is 2000Amp but this each phase taken 1250 But total beldibg load is 600amp or 700amp watt is the problem

1957


What is the Diff. btw Manule Pull Station & Manule Abort Station Switches used in FM200 System??

1853


EXPLAIN METOD OF IMAGE OF TRANSMISSION LINE/ WHAT ARE ITS PRACTICAL APPLICATION?

1878


iam using DM 3251 voltmeter(1 percent accuracy)for 11KV system PT ratio is 11KV/110V.can anybody explain what is the max and min voltage deviation.

2244


How can maintain our H.T. motors used in cement plant. please send me procedure.

5146


What is pole of the system?

1138


why the active power flow of some line is increased when the active power of out is cut ?

2039


v/f drive basic princeple

2469


The series field winding has low resistance while the shunt field winding has high resistance. Why?

1709


explanation of mesh bus bars

2159


describe the constructional features of an auto transformer and its principle operation

2350