Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what happened if power factor is "1"

Answer Posted / jai prakash narain singh

WHEN POWER FACTOR IS UNITY,REAL POWER BECOMES EQUAL TO
APPARENT POWER,IT MEANS KW =KVA
IN THIS CASE REACTIVE POWER IS ZERO,SO NO USELESS
WATTAGE,SAY NO LOSSES.

Is This Answer Correct ?    10 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

WANTCONTACT NUMBER & EMAIL/ WEBSITE TO CONTACT THE SECRETARY,MADHYA PRADESH LICENSING BOARD(ELECTRICAL),K- BLOCK,3RD FLOOR,SATPOODA BHAWAN,BHOPAL

2121


what is basic difference betmeen normal & flame proof motor??

2250


draw vector diagram and +ve,zero sequence diagram of symmetrical three phase fault.

2081


if we run a 3 phase machine on two phase what will happend??? given answer with solid reason please

2129


What is milivolt dop test in Busducts? What is its significance & procedure to do the test?

2133


why we testing the core balance of the transformer before comissioning?

2212


I have 440v power coming to facility,( not being used ) can I buy large generator, (gas) to sell power back to electrical co.

2513


A commercial Building is designed with 14th floor levels with indoor substation of three phase transformer with rated capacity of 1000 Kva.The transformer delivered 65% of its rated capacity at 0.67 power factor lagging.Because of low power factor, the power customer was penalized and certain cost was charged accordingly based on every point percentage lower than 85%.This situation may repeatedly happen on the succeding energy bills of power customer.The power customer is desired to improve its historical power factor of 0.67 lagging and no further penalty be impose by the local power company on the next bill. Q: Identify the appropriate solution you want to offer to Client?.Justify SCIENTIFICALLY and MATHEMATICALLY the principles behind the solution.

1837


What are the effects of adding a zero to a system?

1363


Where is the best place to mount  distribution panel in a house.

2142


how was your last weekend.

1825


Is a contactor (or master relay) required between incoming lines and a VFD? The question goes to safety. If a contactor were used before the VFD and an e-stop engaged then the motor will coast to a stop (i.e. VFD loses power) instead of stopping much faster if the VFD braking fucntion were used. It would make more sense to keep power on the VFD.

2240


Can you explain about Restricited earth fault protection scheme

1904


compare between starting charactristics of synchronous motor with those of 3Q Squirrel cage induction motor

1854


what are factors comes under relay setting (distance relay 7sa52) under OPEN DELTA VTs connection??

2597