d/p flow transmitter LP side give to pressure.what you
geting out put ? how you get(ma)?

Answer Posted / shivu

yahh for DP-transmitter we will be having the two taps at
the side or at the bottom side ,but to know the working of
the transmitter or for the calibration purpose we have
give/apply the pressure at LP-side tapping & the HP-side it
should be kept open for the atmosphere ,,,,,,,,,hence by the
difference of the pressure we will get the MA-output.,,i,e
with respect to the applied pressure

Is This Answer Correct ?    2 Yes 10 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is instrumentation technologists and mechanics?

588


what is maxdna ?. explain about the software details.

3907


2. What is ultrasonic flowmeter?

4436


i have used level transmitter in starch cooking preparation tank. tank total height 2mtr.sometime LT display shows some error value when tank is fully empty and diaphragm side i already checked okay no problem in diaphragm area. field cable checked 24volt and mA shows correct value while tank empty mA is 4mA. 4mA i needed that 0% but display showing 10% or 15% percentage values are varying continously please give any good solution for me.....

1001


Make Heater Process Logic.

1646






In Safe Guarding test what means by "Failed to Danger" ?

1660


Sir, I am working as a Instrument Engineer in Grasim Industries. Can any body provide question answer for interview purpose

1686


Calibration procedure for Electro magnetic Flow meter

4042


Describe the functions of the Operator Interface including the considerations related to alarming and display layout/configuration/layers.

1646


How to check vortex flow meter is in good condition while we do not having calibration setup?

7534


I was working on calibrating turbidity transmitters endress+hauser at effluent polishing plant.We calibrated using NTU buffers.What happened is that when we immersed the sensor, everytime we raise and lower the sensor gradually, the reading will vary.my question is that is there any specifications on what is the required distance from the bottom of the container with buffer to the face of the sensor?Is it ok to install the sensor in a medium which has turbulence specially if bubbles are present?

1737


how to connect transmitter measuring sulfur process? 1-by using long impulse line or 2- by using coated short impulse line

1586


Can please tell mi about SIOS, PRM, SERVER, and what is the diference between PIN LAN, PCS LAN,APC Server, and please send the Doc if possible for referance,mail id patil_amit17@yahoo.com

1456


Explain the key components of control loop?

577


Where are oxygen analysers installed in cfbc boilers? What are their usual readings?

1127