Answer Posted / jai prakash narain singh
first of all i shall expain you regarding IP, IP means
ingress protection, first digit indicates protection against
solid and second digit indicates protection against liquid
for equipment enclosure.lets say IP 11 MEANS SOLID BODY
ABOVE 50 MM WILL NOT GO INSIDE ENCLOSURE AND LIQUID FALLING
FROM TOP OF ENCLOSURE WILL NOT INGRESS.AS IP NO. INCREASES
PROTECTION ALSO INCREASES.
ip 55 MEANS IT IS ALMOST DUST PROOF AND WEATHER PROOF.
FOR FURTHER QUERY CONTACT ME ON MY E MAIL ID.
jpnsingh12@rediffmail.com
| Is This Answer Correct ? | 14 Yes | 1 No |
Post New Answer View All Answers
Compare jfet’s and mosfet’s.
in 132kv substation CRT means
how to calculate magnetic force genrated by a coil ?
Why front mounted CT polarities are always towards breaker?
What is Percentage impedence of a transformer? why it is expressed at a percentage? what is the importance of percentage impedence in case of a transformer?
what is photo voltic cell,& what are the materials associated with that?and any spcifications like volts/cm etc?
True or false question. 1.The fuse provide phase and neutral 2.power loss in electrical circuit can take place in (resistance or inductance or capacitance). 3.two phase system each phase has separated by a phase difference of (90 or 180 or 270 or 45). 4.3 phase balanced star connected load neutral current shall be (line current or phase current or zero or unity)
ACCORDING TO IEC WHAT SHOULD BE THE MINIMUM HEIGHT OF G.I. STRUCTURE OF CT, PT, ISOLATOR, LA?
Can any one provide the inspection procedure of MIMIC for VFD panel? Details: If someone wants to have a mimic in the VFD panel what are inputs considered for the mimic(like on,off,trip) whether we are able to add speed variation in the mimic(if so how can we get) and what are the parameters to be checked in the MIMIC during inspection?
5- What is the task (function) of the excitation and isolation transformers in power plant? 6- What is the task (function) of LCI (A), LCI (B) and LCI (COS) in power plant? : LCI (A) and LCI(B) are load commutating inverter for generator turbine starting. , LCI (COS) is load commutating inverter change over switch
what is the purpose of using filters in a protective relaying scheme?
A power transformer 4MVA/11KV/0.415Kv has been out of use in 12years. what maintenance actions/test need to be carried out before energizing.
Determine a suitable number of slors and conductors per slot for the starter 1 winding of a 3 phase, 3300 V. SO Hz 300 rpm alternator. The diameter is 2.3 m
is ac supply can store
Differentiate between real and apparent power?