WHAT IS THE difference betwwen LT CABLE AND CONTROL CABLE
Answer Posted / m.stalin
LT cable (Low Tension) cable used to carrying the power
supply to load
control cable is used to control the panel equipment i.e
starter, timer etc
| Is This Answer Correct ? | 3 Yes | 0 No |
Post New Answer View All Answers
What is lighting kitts.
why we used ZNO in Lightning arrester.
what is the value of combined earthing in general electrical circiut?
My question is whether bellow formula is correct to find bus size for 46kA for 0.5 second & what is RT in bellow formula. formula to calculate the size of busbar to withstand the thermal stresses due to currents with duration of 0.2 sec to 5 sec. Sp = RT( I x I x t) / K Where Sp – is the cross sectional area of bus bar in millimeters. I - is the value of AC fault current. t - is the operating time of disconnecting device in seconds. K – is the factor depending on the material of the conductor, insulation and initial and final temperature. Value of ‘k’ for copper is 143.
what are the applications of TIG welding
what are the usual topology of transformers at different substations in the power system and why that particular topology is choosen. what are the limitaions of that topology?
How can we calculate the motor frame sizes?
State Maximum Power Transfer theorem.
If rotor works in clock wise what happens
how we can do the insulation on secondary of ct explain and so that tan delta will within limit
Please help me regarding my one concern. - During earth pit testing we noticed that the Clean earth pit and dirty earth pit showing continuity (Resistance value - 5ohm) . I want to know that if both earth pit have separate location and there is not internal looping between PIT then why such continuity is showing on it . Because of this issue the field side all earthing point showing short. In PLC panel we are providing two types of earthing cable which is coming from separate earth pit (Clean and Dirty earth pit) because of earth PIT showing short our PLC is not complying spec . please help regarding this issues.
How to synchoronize the generator (with gcb,GT) to grid????? ????? from Grid iam getting power (rated 400kv/20kv) through GT and its goes to UAT.,,ST.,, now my generator(rated 20kv ) ready.,, now iam closing my GCB.,, in GT iam suddenly giving 20kv on that Gt.,, what will happend
PLEASE ANYBODY HAVE ELECTRICAL CIRCUIT DIAGRAM FOR CHMER PULSE CD 60M SPARKING MACHINE.PLEASE MAIL ME SUPRIYAAYYAPPAN@YAHOO.CO.IN.
What is the procedure/activities to be taken to inject the current more than 2000A by using 2000A Loading Transformer?
How we calculat the NGR of 3phase Generator, Our generation voltage 11KV