WHY 6.6KV MOTORS ARE STAR CONNECTED AND WHY NOT DELTA CONNECTED,

Answer Posted / bijay kuma bhoi

in star connection current is always same in starting and
running period ,so we can use fixed class of insulation
cable,but in case of delta this is not possible due to
changes of current .so all ht motors are conncted in star .

Is This Answer Correct ?    4 Yes 15 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How much earthing frequency is capable?

1582


If o/p power is doubled by how much does the sound increase

640


What is the purpose of stand by earth fault protection for transformer ?

1563


importance of reactive power management

1589


Differentiate between digital phase converter and ordinary phase converter.

770






after how many spot we must chang secondry cable in portable spot welding gun?

1470


In Power Line Communication (PLC) the wave trap is used to block communication signals from entering neighboring lines. My question is this: Why do they allow for different filtering arrangements on these wave traps? Isn't it always going to be a low pass filter since we want the power frequency to go through, and the comm signal blocked?

1485


How to calculate multiplication factor in kva example 500kva ans pls ?

1397




1909


Initially, when the input is not equal to the output — what type of response is this?

671


Where I can get the sample question for post of Junior engineer electrical-II For RRB Bhubaneswar.

1702


how to produsing geretor power

1736


How colour picturetube works & how many year it will works.

1580


How can claculate to attain the desired PF in the line ( HOW Much KVAR is required ) Pls Give the formula? Equate Petrochemical 0 1 how to calculate sizing of NGTR (Transformer rating,Loading resistor value and Current rating of resistor) and what is the X/R ratio. Details : 11kV,Capacitance 1.73532 micro farads,40kA for 1sec. 0 1 What will happened. if we feed 3phase supplay to the stater with out insert the rotor. How much current will flow through the stater winnding? Equate Petrochemical 0 1 What is required of exietation to the alternater. 0 1 why star point of HT motor not earthed? Equate Petrochemical 0 1 Why we are getting low voltage in star connection? Equate Petrochemical 0 2 What's ND relay & it's functions? Equate Petrochemical 0 2 How instantanious short circuit current is calculated? its formula? Equate Petrochemical 0 2 What is servo Motor? What's the advantages of this motor over Induction motor? Equate Petrochemical 0 2 What is core CT & it's function? Equate Petrochemical 0 3 what is meant by star/delta voltages as 440/220 in a 3 phase induction motor, and why it should be connected on STAR IN 3 PHASE SUPPLY L & T 0 4 What is required of exietation to the alternater. KNB 1 23 what is the design voltage for 6.6KV 2000 KVAR HT capacitor? Consultancy 0 3 Pls explain about vfd control?Where it is used, Give some example? siemens 1 22 Please explain me abt PQ diagaram in the power sector. 0 9

1614


An 8 pole, 50 Hz, 3-phase IM is loaded to a poing where pull out torque will occur. The rotor resistance per phase is 0.3 ohm and motor stalls at 650 rpm. The rotor reactance at stand still is A 2 ohm B 1.25 ohm C 3.15 ohm D 2.25 ohm

1757