Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

why neutral grounding transformer is used for generator and
why it is not used for transformers?

Answer Posted / tanvir s.

As far as i understand Neutral Grounding Transformer are used to Ground the both transformers as well as Generators. NGT is applicable (useful) in transformers/generators with delta connection. So during line-to-earth faults, the NGT helps the zero sequence current to flow in the ground. Any unbalance in the load distribution between the three phases is passed thru the neutral, which is not available in case of delta connection. Hence the NGT.

Is This Answer Correct ?    9 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how commomn gate triggering is given for TRIAC ? other thyristor wont be efffected?

2423


Advantages/Disadvantages of earthing of neutral bus on MSB instead of separate neutral earthing for transformer/DG sets feeding to MSB

2787


In between UPS out going changer over switch and ups raising main input, both side cable gland producing heat but the cable doesn't get heat,Why?

2260


What are the limitations of Kirchoff's laws?

1581


what is the formula for hv test for cable and circuit breaker..????

2029


how to calculate the surge level of surge suppressors related to the SF6 cicuit breakers?

1961


in ACB breaker requireding 3200Amps. buscoupler getting OFF mode and again it reset and getting normal position give me a required answer?

2330


Difference of induction motor & servo motor ??

1819


How does the slip regulator works as a startor

1957


sir vizag steel ka junior trainee ka paper kitne number ka ayega

2235


What is the role of power pack in substation protection system?

2688


How to calculate the time setting for star connection in star delta starter? For example 10KW 3PH Induction motor.

2619


why normally Generator rating are between 11Kv to 22Kv?

4646


How PSV sizing being done

2313


i am electrical and elctronics engg passed out in 2009 want to attend for reliance placements.plz send me apttitude ,technical and hr question answers to my mail plz. my mail id-kat.bindas@gmail.com

2016