10. THE MOST COMMON TYPE OF THREE PHASE IN UNSYMMETRICAL
FAULTS IS ........
Answer Posted / thuranga
L-G fault is most common in distribution systems,as the
trees and buildings are near by the distribution lines,
while in transmission lines any of the fault can
occur....but occurrence of fault is very rare,as all the
protection steps are taken,and the fault may occur mostly on
the degradation of the suspended disc insulators.....where
the leakage current flows through the pole/tower to the
ground, through insulator.
| Is This Answer Correct ? | 5 Yes | 1 No |
Post New Answer View All Answers
How to use computer cpu ups use for home inverter circuit board
how make megger test for control cable like 12c x 1.5mm and what it apply voltage and test timing details.
in a solar power plant,we are going to step up the voltage 350V to 33kv, and to 132kv GSS. i want to ask that if it is possible that 315v/33kv is not possible because we also use 315v/11kv. or it should be 415v/33kv? is it effects generation or losses? the second question is-generation is depends on LV winding? or LV winding design for generation voltage?
why induction motors are rated at 0.8 power factor.
What is the Difference between Ac Drives and Dc Drives? According to application, speed, Torque, cost, Reliability, Construction, Motor etc... Thankyou !!!
if we give 60 hz single phase supply to the transformer used in europe , than what will happen
What is the difference between AC and DC injection methods for rotor earth fault protection
What types of question are done for diploma students in aptitude test
how can we change the polarity of Alternating current rapidly? how frequency of ac can be controlled and changed easily?
please send me previose rrb junior engineer qustion papers
In Air circuit breaker LSIG protection unit is used. Without fault in cables (2 runs 3Cx150Sq.mm Copper, 1Kv grade, XPLE armored cable IR value is more than 550Mohm @ 500V Megger) and load section Long time Overcurrent protection is triggers and trips the unit. We changed LSIG protection with new factory tested unit. Even then fault is persisting. Please suggest the possible causes
Explain thin film resistors and wire-wound resistors
Dears we deal in Chemical are Plate earthing. Kindly call if any requirement and questions. Tech Earth Solutions Mohit Verma 8791071007
how to measure the transformer resistance values(dyn11)?and howmuch the minimum value?
hi if anybody got model questions for cpcl Grade'A' electrical engineer position.send it to my mail please krishkumar22@gmail.com