WHY HUMMING SOUND OCCURED IN HT TRANSMMISSION LINES?
Answer Posted / subhash tp
The humming sound is coming from transformer
at the time of working is due the magnetic expansion
and de-expansion at the ends of transformer cores.
At the time of working the transfomer core ends are
expanding when supply voltage occures its positive half cycle
and the transformer ends are de-expanding at the time of supply voltage occures its negative half cycle .This expansion &de-expansion is making humming sound,and also this wii continue during the transformer is working.
| Is This Answer Correct ? | 1 Yes | 6 No |
Post New Answer View All Answers
What is the reason behind current flow(20 A) in amain earth cable of an SMDB? Is cuurent flow(45A etc) through a neutral cable acceptable?
What is gain margin?
when generator short circuit condition, the current how dissipates. or at short circuit voltage not available then current how can flow?
what is the step by step formula for calculating bus bar phase and neutral size of a panel board.suppose the incomer of panel board is 100A..???step by step answer please
Why derating factor os applied on Cables?
what is the voltages using in movie theaters??? why ??why not other??
how to find the torque of the single phase synchronous motor by doing an experiment
1.what is difference between ATS & STS main use. 2.what is difference between ACB& VCB With symobles,and main partes, manimum range. 3.How many types of relays and main function.
what is the mechanical safety of DG ?
what is negative d.c. voltage, why this voltage is used in base transciever station.
If i have two 3000 kW motors and the whole facility requires a 10 MVA transformer. What would be better installing two 5 MVA transformers(one for 1 motor ) or just a single 10 MVA transformer for both of them. Give reasons for your answer.
Is better to supply the voltage for static exciter from the auxiliary power source or from the SG terminals? And why?
Why 30kw 40 hp 4 pole 3ph induction motor over heated?any steps on reduction in heat?
how to calculate cooling requirement of datacentre from electrical load?
How do i perform grounding of star point of Genset (400V) for making connection with step up transformer of DELTA-DELTA (400V to 20KV) ? while Genset itself has its own neutral and grounding bus bar inside genset breaker box whereas we have another neutral and grounding busbar in synchronizing panel next to genset at maximum distance of 6meter, would someone pls advice if we can only perform neutral grounding in synchronizing panel or should we ground neutral on both places inside genset breaker box and synchronizing panel.