The earth pin of some three pin plugs are seen split. why?
Answer Posted / kts.murthy
THE FAULT CURRENT ALWAYS FLOW THRO EARTH ONLY. THE VALUE OF
THE FAULT CURRENT ALWAYS HIGH FOR THE SMALL TIME PERIOD.
IN THREE PIN EARTH PIN NEED PERFACT CONTACT WITH TENSION.
SO ALWAYS EARTH PIN SPLIT CONDITION.
| Is This Answer Correct ? | 7 Yes | 0 No |
Post New Answer View All Answers
How can find thermal state value in relay for calculate thermal overload.
use of PIR in ehv breaker
what is the formula for efficiency of francis turbine and generator for hydropower? what is best way to select francis turbine and generator?
How time response of the system is divided?
what is the difference between electrical choke and electronic choke?
Show Details FROM:Muhammed Ikram TO:qa@allinterview.com Message flagged Saturday, June 4, 2011 10:07 PMMessage bodyHello all, i want to ask a question to all of you that what is VMM (voltage monitoring module )? how it work,s? i heard somewhere that it compare 1 phase voltage to other phase voltage. but there is also some setting on it. how to set it,s setting. please tell me briefly. Thank,s and Regard,s. Muhammed Ikram.
how 650 volts creates? where is use?
Electrical 'C' license full abbreviation , and full form
when will be the iocl interview results i faced interview on 8th september 2008 iam from electrical branch i faced interview for the post of electrical engineer??????????????????????//
How dia computation perfomed in cold rolling mills .
How can a equal potential zone be carried out in conductors?
We have drive feeding an output contactor for a 5000 hp motor @ 5kV application. The motor FLA is 629amps x 1.25% service factor = 786.25 amps The cable that we current have in place between the drive and the output contactor is 350kcmil- MV-105 (parallel cables). Per the NEC table 310.60 (C) (69). This show the cable ampacity is at 615 amps per cable for a rating of 1230 amps. We have derated the cable for the cable tray and the multiple cables application and our calculations show that after the correction factor factor we are at 922amps. 1230 amps x .75% correction factor factor = 922.5 amps. The customer is driving us to then use another safety factor of .25% off of the already derated cable. Can you please provide a longhand calculation for your solution on this application?
transformer spections :: input voltage 0-110-230v; output volage 0-10-12-14v; amp=3A using CRNO CORE, capcaity=50VA primary turns = ? ; secondry turns =?
best manufacturer for busbar for outdoor switchyard having double bus bar scheme, can any one share technical specification of busbar. 132kv voltage ?
What is the basic principle of welding process?