What is the difference between radar and ultrasonic level
transmitter? Which method is best and more accurate?
Answer Posted / wissam almajeed
For liquid measurment application,the radar signal did not
affected by temperature and pressure while the ultrasonic
signal strongly affected by temperature and weakly by
pressure.
| Is This Answer Correct ? | 19 Yes | 14 No |
Post New Answer View All Answers
How do you identify an orifice in the pipeline?
How many types of sensor
if in a level tx height is given, how u calculate the ranges of the tx?
What are the charcterstics of a P&ID controller block for Governor speed raise or lower for a load sharing functionality between 4 Gas turbines in droop mode.
How many ohms are required for proper earthing?
what is the procedure of O2 sensor(ABB) calibration?
what is zero and span ?
I want to apply for the universities in US,but i got the GRE score of (650+300=950)TOEFL 69/120.Is this score sufficient for applying universities please i am married i need to go to US because my husband didn't get H1 yet.please send me suggestion
How a conductivity sensor & analyzer work at boiler, whats the principle & science is beyond this,How conductivity sensor sence & convert signal & move toward analyzer & analyzer show reading in percent? also what is temperature compensate option in conductivity analyzer
HOW TO CALCULATE ACCURACY OF AN INSTRUMENT. WHICH IS COMPITABLE FOR USE.
all types of liquid analyzer principle with drawing?
hi! i want to know about mpse exam.
A PLC is programmed to drive three motors A, B and C as follows : After running motor A for an hour, motor B should get ON and motor A should get OFF. And after running motor B for an hour, motor C should get ON and motor B should get OFF. And after running motor C for an hour, motor A should get ON and motor C should get OFF. (That is, a cyclic repetition with time period one hour) Now, the second condition is: If any motor gone faulty and is tripped, the consecutive motor should get ON and the faulty (tripped) motor should be eliminated from cyclic repetition. The remaining two motors should bear the cyclic repetition of one hour each. (For healthy motor take logic as high and for tripped motor take logic as low) Now, the third condition is: When motor A load(Amps) exceeds 60% of its rated load, motor B should get ON in parallel to motor A. And when both motors A & B are running in parallel, and if their load exceeds 60% of their rated load, motor C should also start in parallel to A & B. [Here the cyclic repetition is eliminated, until their loads become normal(40%)] [Take logic high(1) for load at 60% and logic low(0) for load at 40%] Now draw a flow chart or a ladder diagram to fulfill the above condition.
Explain the key components of control loop?
What is critcal speed. what is resonant frequency. why we want to cross crtcal speed on higher RPM (early).