Why Ferranti effect not occurs at full load?

Answer Posted / vishaljadhav001

When supply side C.B. switched,at receiving end voltage
will not appear immediately."Wavefront" is formed.At left
of wavefront Vtg & current occurs,but at right vtg &
charging current is zero.
This wavefront travels from left to right with wave velocity
(v) which depend upon how fast inductance,capacitance reach
max.current & current .At no load capacitor charge through
inductance step by step.When line charged Vr=2Vs.When load
is connected this capacitor discharged,so vtg appear at
load.so that ferrenti not occurs at full load.

Is This Answer Correct ?    3 Yes 9 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is a fuse? How does it work? What are materials used?

1638


A 500 V shunt motor runs at its normal speed of 250rpm when the armature current is 200A. The resistance of the armature is 0.12 Ω. Calculate the speed when a resistance is inserted in the field reducing the shunt field to 80% of normal value and the armature current is 100A.

2134


I Want randstand placement papers

1465


If the line voltage is reduced to 75% of its rated value then by what percentage current will reduce ?? 75% 25% 50% no change and why ?

1859


What are the advantages and disadvantages of closed-loop control system?

813






hai iam arunkumar. i have applied for an section enginner in rrb. i want lat 5 years solved question papers. if u have please sedn it to arun30682@gmail.com

1428


A Generator is in running condition and Rotor earth fault alarm is coming.How to check on line(i.e in running condition) whether there is actual earth fault in rotor or not.

1561


why induction motors are rated at 0.8 power factor.

1626


Two liquids hot and cold in two vessels are there and an metal bar acts as a conductor of heat between the two vessels. what happens then. what happens after 24 hrs?

1789


In three pin plug 6 amp. 220V ac rating. Why earth pin diameter is higher than other two pin? What its purpose ?

855


Differentiate between voltage and current feedback in amplifiers?

720


is it possible to say motor horsepower number without seeing name plate(when name plate damaged)

1690


How to determine alternating current frequency?

780


how will calculate the safe starting current of 3-phase squirrel cage induction motor?

1540


How do i perform grounding of star point of Genset (400V) for making connection with step up transformer of DELTA-DELTA (400V to 20KV) ? while Genset itself has its own neutral and grounding bus bar inside genset breaker box whereas we have another neutral and grounding busbar in synchronizing panel next to genset at maximum distance of 6meter, would someone pls advice if we can only perform neutral grounding in synchronizing panel or should we ground neutral on both places inside genset breaker box and synchronizing panel.

1370