What is GD2(kg-m2) for Sq. cage ind. motor?

Answer Posted / gyan guru

gd2 is the value which is meant to check that whether a
given motor will mingle with an impeller or not. Its a
sought of age of fan and motor.

Technically , it tells us about the measure of the ability
of the motor to attain its a rated speed from rest.

This is calculated with the formula
4 x m x r2

m = mass of the impeller

r = radius of gyration

r shall be 0.4 times the radius of impeller

I hope its sought of clear now

Is This Answer Correct ?    40 Yes 29 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

As per standard, transformer body earthing and other Equipment earthing (Equipment earthing) did not connect. but in LT side termination we are doing metal glanding in both side Transformer to PCC Panel through armoured cable, now X'mer body earthing and PCC Pane earthing (Equipment earthing) both are connect.is this safe for X'mer or other equipment?

1193


if 6 earth pit value is 1.5 ohm then what should be the number of earth pit to make the value .8 ohm

1700


Define unilateral circuit?

700


what work will do diffrential realay DG set

2325


what is the power rating of CPU, CRT type moniter, LCD type moniter,scanner Approx.

1763






what is the mechanical safety of DG ?

1689


what are the condition that makes hooter blow?

1860


what is the ckt diagram of a tubelight and is it the simplest ckt of electrical engineering and also the component?

1840


Are Refrigerators & Deep Freezers the Inductive load ? How to calculate the Power Factor & hence the Output Power for them ?

4626


The SFC of an engine is 0.25 kg/kW hr. when the fuel used has a calorific value of 36000 kJ/kg. the thermal efficiency of the engine is

1284


I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?

1414


could an induction motor be used for regenerative braking in electric-train control? in this type of application would some scheme have to be devised to obtain low synchronous speeds while braking? would induction-motor drive, therefore, be suitable for passenger service?

1586


What is force on a conductor in a magnetic field ?

618


Can you any one explain application of buccholz relay operation and pressure relif device operation of power transformer

1439


Why HT 11 KV Slipring Motors are connected in star ?

1766