Answer Posted / sunil guru
SKIN EFFECT--- IT IS THE UNEQUAL DISTRIBUTION OF CURRENT...IN THIS THE CURRENT FLOWS AT THE SURFACE OF THE CONDUCTOR RATHER THAN BULK.....SO CAUSES HEATING OF THE CONDUCTOR AND THUS THE LOSSES ARE INCREASED...
SKIN EFFECT MAINLY DEPENDS ON
1.SURFACE OF THE CONDUCTOR
2.MATERIALS USED IN THE CONDUCTOR
3.FREQUENCY
FOR ANY DISAGREEMENT MAIL ME AT PARMAR20072008@YAHOO.COM
| Is This Answer Correct ? | 0 Yes | 0 No |
Post New Answer View All Answers
I am inpecting a 10kVA UPS what tests should i do and should i observe?
why only exciting current is shown not primary current in transformer???
What is transient response?
Mention the difference between Analogue and Digital circuit?
how to calculate differential current when we testing differential relay..suppose we have 1000kw generator,630amp VCB,what value we should put /inject so that relay trip the VCB? PLLZ justify ur comment
why the pf of semiconductor device is improved the electrical devices
Dear sir, In our plant have Station Transformer having capacity,i want to know, why LV side 40 - 40MVA is given? & how we can get 6.3 KV supply from tertiary(i.e. Open delta connection), Vector Group YNyn0 - yn0 +d MVA Rating 80MVA / 40 - 40MVA + 26.7MVA Voltage rating 420 (Tap range +6,to -10)81.25% /11.5KV - 11.5KV +6.3KV
how to calculate energy of 3-phase motor?
Purpose of providing neutral isolation panel for parallel operation of diesel generator
What is the direction of current flow in ct secondary...means if the current is flowing from P1 to P2 then what will be the direction of current flow in ct secondaryw
what is sustainable current of any conductors . a bare busbar or pvc cable has different sustainable current .
what is errection pcbs?
What are the internal and external faults?
What mean by MLTP
(1)The demand for electricity , the amount of renewable generation available, the amount of fossil fuel generation available and the cost of the fossil fuel generation are shown in table below period(hrs) demand(MW) renewable (MW) fossil- fuel(MW) cost of fossil fuel(MW) 00.00 - 01.00 2000 1800 2000 30 01.00 - 02.00 2300 2500 2000 30 02.00 - 03.00 2500 2700 2100 45 03.00 - 04.00 2900 3100 2100 50 04.00 - 05.00 2700 2600 2500 45 05.00 - 06.00 2400 2000 2700 50 06.00 - 07.00 2200 1800 2000 36 07.00 - 08.00 2100 1600 2000 36 Assuming that the renewable generation incurs zero cost, determine an optimal generation schedule(specifying the amount of renewable generation and fossil fuel generation used in each period, the cost for each period and the overall cost for 8 hours.)