Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

define the power factor in one word

Answer Posted / bhanu

true power/apparent power

Is This Answer Correct ?    15 Yes 2 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

what is class of SPD and dittels of all class ?

2080


how we can do the insulation on secondary of ct explain and so that tan delta will within limit

1898


What should be the height of basement according to NBCC code?

2174


If a shunt Dynamo has induced emf 100V and 0.4 ohm resistance and battery of accumulator of open circuit emf 110V and 0.5 Ohm resistance are in parallel what is common terminal potential difference?

5181


how can service sitting be setted for MCCB?Example for sittings IR (CURRENT RATING),IS(CURRENT STARTING)IO (current operating)?

1811


How to Decide the Location of Earth pit for Compressor in Oil Depo? and How to measure the resistance of earth pit Pls explain me with the help of Circuit Diagram?

2469


why magnetising curve not start with zero voltage?

2260


Dear friends, i would like to know that what is the exact function of 'exciter winding' & 'aux winding' in Alternator?

1972


Write the force balance equation of m ideal mass element.

1202


Why do you have to use Protecion relay with the function MTB ( Mechanical Trip Button ) for electrical system.

2165


Is a contactor (or master relay) required between incoming lines and a VFD? The question goes to safety. If a contactor were used before the VFD and an e-stop engaged then the motor will coast to a stop (i.e. VFD loses power) instead of stopping much faster if the VFD braking fucntion were used. It would make more sense to keep power on the VFD.

2134


How to design harmonic filter at the project stage without nowing the harmonics levels

2188


What are locations arc protection relay is fixed.

1835


How to test Alternator stability test for REF relay

1454


The magnitude of sum of two sinusoidal av voltage is equal to 230 volt.the magnitude of each individual voltage is also equal to 230 volt.what must be the phase difference between voltages?

1581