hello to all, this is what i think---
this is a great question but reactive power never become
zero,may be for some <1sec or in instances.
if it becomes 0 its a great help to power system to supply
power at high efficiency to understand this u need to know
the source of reactive power,generator produces reactive and
real power p+jq,so q is due to excitation in generator ,and
P-real power is due to armature or to say rotating part of
machine.
as components get connected to GENERATOR,like
transformer,transmission line and distribution system,this
components absorbs or produce reactive power,
reactive power is a imaginary term used by engg to maintain
voltage or to say power at the load,basic thing here is
magnetic field----absorbs reactive power,electric field
---produce reactive power,
transformer----absorbs reactive power
transmission line-light loads-produce reactive power
heavy loads-absorbs reactive power
now advance in connected equipments which are all mostly
these days electronic component so reactive power is
generated i,e --static relays etc
at the end how inductive and capacitive components behaves
in power system----which was answer by many above
every answer above related to voltage quality or power
quality so i have added the basic thing to understand
reactive power movement u need to trace the sources in POWER
SYSTEM.
HOPE my answer could help some one
| Is This Answer Correct ? | 19 Yes | 2 No |
Post New Answer View All Answers
How we can calculate the Amps for the cable Ex:- For 1sqmm wire how many amps we can draw (calculation)
If I want to lift the water at a height 50m from ground level through two inch(diameter) metal pipe then what is the capacity of motor pump is required? is it possible in single phase supply or not?
What is the working principle of CFL & T5 tube light & 40W tube light with electronic ballast?
I am getting above 60 V as open delta voltage against single phase unit ICT at tertiary delta formed and ICT getting trippped on NDR. ICT tested and found in order. PTs provided on tertiary are tested and in order. what may be the reason?
1.how many types of relays? 2.difference between ATS& STS?
How to define Kirchhoff current law and voltage law along with simply examples.
How to select a contactor? How many types of contactors are available
What is main cause of cable's terminal point burned in Lug on high temperature although lug and cable selection is ok as per stantard and also tightness is ok as per situation. so please take in deep and tell correct answer thanku.
Write the force balance equation of m ideal mass element.
What are the weight of 800KV DA,DB and DC type tower ?
What are marginally stable systems?
I'm generating a pulse of 3V with frequency 80Hz (12.5ms time period) and pulse duration 0.125ms and feeding it to a transformer since i want the pulse to get amplified around 60V. At the output amplification s happening but the pulse is changed to a spike, can you tell me what could be the reason? (an ordinary transformer 220V-12V stepdown transformer is reverse connected ie. now it is 12V-220V stepup and voltage amplification happens)
State the methods of improving power factor?
the grid connection required for a 50 MegaWatt fotovoltaic powerplant is higher or lower than 35kv (high or medium tension)?
how withstand of hi-pot test outputs of transformer wire 2.5mm