Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

how we can differentiate a motor and a generator just by a
glance?

Answer Posted / amrinder

theres a prime mover in generator . for eg.. a diesel
engine in diesel generator. so u can always makeout.

Is This Answer Correct ?    0 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how to deside the capacity of chock for drive?

2048


Vaccum circuit breaker

1384


why US countries maintains 110v and 60HZ

2181


how hydrogen cooled alternator undergo maintanence ? that is hydrogen when come in contact with air can result into explosions .

1910


Differentiate between magnetic field and magnetic flux?

1128


can any tell me why slope 40% and 80% is calculated in differential protection?

1880


On a 3 winding transformer YNynd11, how do you apply REF protection to the Delta tertiary winding that is supplying auxiliaries to a substation?

4368


How do you calculate the actual power consumption of an inductive load appliance. Say, a deep freezer of 200watts

2126


I have a current transformer with 1 main reading meter with transformer outside the building and a control panel having 5 CT reading meters with black round coils inside the building. I want to know, A) when current pass through the Transformers, will the current be reduced or be the same and after that B) when current pass through the CT meters with black round coils, will the current be reduced or be the same. C) in the above process will the reading of the main meter be same or different, from the total reading of all the 5 CT meters.

1800


If there are two transformer having rating of 2.5mva, 6.6kv/440v(satr-star),and the load is 600kw then what is better to maintain less losses in transformer having both transformer in parellel or only single transformer connected to load? Please give calculated answer

2700


why do we not use equivalent voltage source in negative sequence equivalent ckt.

2037


how is the connection of a 3 phase ct trivector meter done on a pole mounted transformer

1353


how to put cable sizing and cable glands size for respective cable & Cable Lug size in a DB sectors???

2158


in dc suppy frequency is zero why? if dc frequency is zero how to exist dc transients and ac transients

2110


What will happen if the voltage in my house drops from 220V to any lower voltage?

2191