Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the function of breather in a transformer

Answer Posted / virendra

If anybody have seen the transformer carefully then you
must notice that breather is installed at the vent pipe
connected to the Oil tank & the open end of the vent pipe
in tank is on top.
In any kind of fault condition , if the heat is produced &
Oil gets expand then it will increase the volume of oil in
tank & excessive oil will be get drain through the way of
vent pipe , but in the healthy condition only are passed
through the vent pipe & obvisiosy air definately contain
the part of Moisture & as the moisuture is the one of the
enimy of electrical sustem , it needs to be prevent while
enrering in to the transformer . for that breather is
arranged the dry silica gel is put in to breather & once
the air passes thorogh breather as per silica property it
will absorb the moisture & change its own colour to the
pink,. once it shows the pink colour immediately open the
breather . remove the silica & apply heat for some period
of time & again you can re use it.

result shows that moisure can reduce the dielectrica
strengh of oil.
the good quality oil can sustain its property up to 50 KV &
the oil with some oil gave away at 18 kv.

Is This Answer Correct ?    16 Yes 8 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

What is the approximate value of stacking factor?

1156


What is the difference between rated and per unit in transformer?

2188


i have 90kw motor.so i choose connect cable .please what is parameter checked so please give to formula

2201


How to detect voltage vector shifting in interconnection protection.

1899


Is there any specialised book to refer about fault level calculation both in MV and LV side??

2063


what is data block in plc ? How the values of data block are written and read by hmi ? what is the difference between function and function block ?

3410


what is the Earth Voltages in Power Plants, Sub-stations, Industries, Residential & Commercial Buildings.

2099


What are the uses of stepper motor?

1239


1.main parts of generator? what is used A-check,B-check,C- check? 2.what is FM200 system in data centers? 3.difference between pac,ahu?

2125


What will happen if a dc source is given to a tubelight. Will it work or wont it work....

1972


Where servomechanism is used?

1086


what is 400kv doble circuit quadpole tower?

1941


What is the distance between each insulator in 33kv transformer and how can it calculate

2182


what's the difference between 'shaft power demand' and 'BHP' , when we consider electrical load list.

1512


Consider three heater bank connected in 3 phase star with neutral.Each heater bank connected in each phase.So each phase get 230 volts supply.my question is,during balance condition, current flow in neutral or Not

1631