Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

Why transformer neutral earthing? What is advantages?

Answer Posted / narayanan

protect to the transformer,
human safety
short circuit for protect the transformer
eb line neutral earthing is not work to support neutral
earth
constant voltage

Is This Answer Correct ?    5 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

List some examples of renewable energy?

1188


What are the insulation standerds for eg H clase and how many insulation standerds are there and its standerds??????

1950


what happen as when voltage drop(or may decrease) ? in case of atomic base theory?

2019


what is the use of sdf?

2096


What are the main parts of central chiller plant? Explain the function of each stage.

4797


mention hazard experienced during installation

1970


why does the magnetic balance tests at transformer?

1938


How work of capacitor in dc supply...???

1596


how can you size an automatic voltage regulator?

2350


From what on-site components does the HT panel monitoring the bus-bars in a 11kV system take inputs?

2001


in HT service 3ph 4 wire service Y-phase voltage shows zero . whether it is meter fault? or what be the reason ? if y-ph voltage zero ,can current is recorded? reasons for failure?

1922


IN induction motor pf is increased using capacitors.what will be the effect on motor and system when very large capacitor is accidently installed and pf goes leading.

2135


What id difference between power and energy?

1329


I meggared my 2c*70 sq mm AL AR XLPE cable. its one end show 50 M ohm . is my cable is safe for laying. I have only one phase and neutral.

1874


Sir, My doubt on cable sizing calculation, Load:74 KW calculated cable 1 run 50mm2. Now client asking us to reduce cable size by increasing runs. Sir, My question now when my mind strikes with 2 options 1) Divide load 74/2 = 36 and calculate cable for 36+36 making it 2 runs or 2) Simply i can divide 50mm2 /2 ie. 2 runs of 25mm2 Please suggest me sir

1929