Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is Meant by Load factor in Power plant?

Answer Posted / zan

In electrical engineering, load factor is the average power
divided by the peak power, over a period of time. The peak
may be a theoretical maximum, rather than a measured
maximum.
In the electricity industry, load factor is a measure of
the output of a power plant compared to the maximum output
it could produce.
The two commonest definitions are:
• the ratio of average load to capacity
• The ratio of average load to peak load in a period.
Assuming the first definition, a higher load factor is
better:
• A power plant may be less efficient at low load
factors.
• A high load factor means fixed costs are spread
over more kWh of output.
• A high load factor means greater total output.

Is This Answer Correct ?    21 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

acb(AIR CIRCUIT BREAKER)NOT CHARGING AUTO

2452


how to synchronize 3 phase slip ring induction motors of different ratings.

2351


how to calculate the earth fault current

2573


How harmonic block test are conducted on relays ( Siemens,Areva ect )power transformer using omicron kit?

2344


A Generator is in running condition and Rotor earth fault alarm is coming.How to check on line(i.e in running condition) whether there is actual earth fault in rotor or not.

2010


Differentiate between ideal and non ideal current sources?

1207


In an ACB shunt trip coil and undervoltage coil operated normally( breaker open and charged). But closing coil not operating untill manually discharge and recharging. Any help.

1799


Can any answer me ,What will be the range of C.T coil for L&T energy meter EM301 used for 180 kva DG set

2237


what is the role of energy meter in distribution system ?

1244


Why single phase induction motors are not self starting ?

1706


Work done in a free expansion process is

1199


What is the basic principle of operation of alternators/dc generators?

1146


can any one suggest paper presentation topies for electrical engg?

2049


Is it possible to operate a synchronous 2-poles turbogenerator with a still-in-place faulted bar but electrically disconnected ???? If yes, should I act on the other phases as well ???

2010


concept of busbar and load dispatching..?

2496