Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the fundamental cause of transients in power system?

Answer Posted / iamdon

A power system consists of many circuit elements which can
be approximately modeled as a complicated network(grid) of
Sources, Inductors,capacitors,Resistors etc.The inductor and
capacitor stores energy in their magnetic and electric fields
respectively.

Whenever a power system deviates from its normal operating
condition(due to faualts,perturbations,switching etc)the
redistribution of stored engery takes place.This is because
configuration of circuit changes considerably from pre
perturbation to post perturbation condition.

The redistribution of energy is not an instantaneous
phenomenon.It takes some time(order of micro or milli sec
depending upon the time constants of circuit elements)
to redistribute the stored energy in circuit elements, after
perturbation,which is described by transients in power
system.

Author:arbelectbit@yahoo.com

Is This Answer Correct ?    6 Yes 0 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how to design the heater in temperature control unit to heat 50KL of water?

1909


why core is useful for a transformer ?and also in its operation ?

2092


high voltage transformer input voltage,current and amps rating..distributed transformer input voltage,current and amps rating...

2004


What are test values for an 63 KVA and 100 Kva Distribution Transformers for the following typical tests 1)Magnetic balance 2)Short circuit test 3)Open Circuit test 4)Vector group confirmation test .please give me the standard values for all the above tests.

2710


What are :- AC Distribution Board (Single & Double Front) DC Distribution Boards Distribution Board LT Breaker Panel.

2083


how tto ingress mw in turbine explain.procedure ?

2292


What is conventional thermal current (Ith)

4434


If you have an earth with pilecap then your resistance is really low. why and how?

1988


how  do you choose the cable size as per amps rating & the voltage drop for the same.

1775


please give me all the Alarm .Trip ,Safety Relays & Conditions of Chiller mail me on ashokbabunhce@gmail.com

1819


Power Factor Correction Panel (Manual & Automatic)

2218


In india, according to trade theory above 5 HP motor reqired star delta starter. But we R connect 11 KV motor with 14MW in Direct to line ( With VCB starter combination) Can U Guess, How it is possible ?????

2135


1.why are not using acb 33kv ht side? is there any problem 2.what is difference between acb,vcb,sf6 breackers? 3.what is the function of invertor and convertor in ups?

2137


HOW DO YOU CAN CHECK A 15KV DIODE, WHETHER IT IS OK OR NOT?

2037


For small size, high frequency coils, the most common core material is- a. )Air b. )Ferrite c.) Powdered ion d.) Steel

2983