Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is the main purpose of line PT and bus PT?

Answer Posted / ramji

Line PT has metering and Protection Cores. Its main use is
to mointor the Line Voltage parameters and is widely used
in protecting Lines in case of Faults occuring due to Phase
to phase faults and phase to earth faults which comes under
its review.

sometimes it has a core for meeting synch with respect
others incase the line breaker opens

Bus pt has metering core and protection core for BUS BAR
protn which mointors the faults in all the buses with
respect to that in a particular substation only

Is This Answer Correct ?    7 Yes 11 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Explain cos(theta) and Sin(theta)

2155


List the characteristics of filter?

1109


Is there any type of starter for DC motor other than two point,Three point and Four point starters?

2099


What is the lower limit of break-down voltage of converter transformer.

1965


What is power factor why we should maintain the power factor unless what will happen

1976


what is droop control?

2249


why and where we use early make & late break contacts in protection?

8375


Draw the circuit of clapp oscillator?

1182


Define stepper motor. What is the use of stepper motor?

1298


how can check the resistance of battery contact?

2264


In Air circuit breaker LSIG protection unit is used. Without fault in cables (2 runs 3Cx150Sq.mm Copper, 1Kv grade, XPLE armored cable IR value is more than 550Mohm @ 500V Megger) and load section Long time Overcurrent protection is triggers and trips the unit. We changed LSIG protection with new factory tested unit. Even then fault is persisting. Please suggest the possible causes

856


1))why we run three phase or three different circuit from a single conduit 2)) why not two circuit of different phase run in same conduit?? and why we run same three cicuit of same phae run in single conduit??

2631


what is a bus riser in power system and why it is used

46355


What is the limitation of kirchoffs law?

1172


draw singleline diagram of star to delta and dol starters

2306