Answer Posted / viswanath
D.g pump means it is not a pump it is FIP- FUEL INJECTING PUMP.
The main use of the FIP is supplying the fuel to the
cylinders to maintain crank shaft speed as a Synchronous
speed(1500rpm)
USE;
1)FIP- IT IS USED FOR MAINTAIN SYNCHRONOUS SPEED
2)PRIMING PUMP - FOR OIL CIRCULATION IN HIGH RATING D.G
| Is This Answer Correct ? | 5 Yes | 0 No |
Post New Answer View All Answers
I am using submission of two ct in one and half scheme for 67/67N protection. Both CTs star point is grounded separately near ct box.Will two point ground give wrong tripping to 67/67N during fault or no matter.
working principle of AC Servo Motor with its construction
How can I calculate ISF of current transformer?
IF HT CAPACITOR IN ON POSITION IS THERE ANY LOSSES I.S I SQURE OCCURS IN THE SYSTEM
how to calculate the surge level of surge suppressors related to the SF6 cicuit breakers?
how i can calculate the size for fire cable
What are the disadvantages of autotransformer?
What is the operating principle of turbo-generator.
Between educational qualification and practical work experience, give us a brief explanation on your practical experience in your past Endeavour that you performed well to the satisfaction of your past or present employer?
can anybody send me syllabus of rrb section engg (electrical). and also send previous question pepar...
How does a tertiary winding filter harmonic(espcially 3rd one) from entering into load system?
WHY EXCITER PHASE SEQUENCE ARE OPPOSITE THAN STATOR SUPPLY PHASE SEQUENCE IN SYNCHRONOUS MOTOR >
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
how commomn gate triggering is given for TRIAC ? other thyristor wont be efffected?
What is the power factor of a transformer at no load?