Why different values of B’s (magnetic flux density) are
chosen for DC machines and Induction Motors?
Answer Posted / iamdon
Induction Motors are designed for COMPARATIVELY LOW VALUE
OF B.Because if we select higher value of B,the magnetizing
current requirement for establishing the working flux in
the air gap will became high.This reduces the power factor.
This condition is undesirable hence must be avoided.
DC machines are designed for COMPARATIVELY HIGH VALUE OF B.
Because if we select lower value of B,the amount of force
developed will became small.Since there are large spaces
available on poles,so we have no difficulty in putting
extra number of turns on it for getting higher value of B.
Author:arbelectbit@yahoo.com
| Is This Answer Correct ? | 2 Yes | 0 No |
Post New Answer View All Answers
11kv/433v delta/star distribution transformer primary side full load Ht current is 83.33A in , but input side VCB rating 800A.why?
How many capacitors using in LT panel as per Govt rules?
WHY RATING OF VCB NOT LESS THAN 630A
According to underground cables a) stress b/w sheath & conductor is high b) inrush of core & conductor
I have one ct of ratio 3000-2000/1 Amp its knee point voltage mentioned on name plate is 500-333/30mA-50mA at Vk/2. in secondary box there is three terminal named 1S1, 1S2, 1S3 then on which terminal obtained the knee point voltage ie 1S1-1S2 OR 1S1-1S3 & also specify the knee point voltage for the ratio 3000 from name plate.
What is the comparison of PILC and XLPE cable
how do we calculate length of starting time and repeated starting of a direct online starter?
Why delta star trformers are used for lighting loads?
What are your future plans for the company if permanently employed?
What will happen if the d.c. Machine is operated below rated speed?
The loads are connected with phase and ground then why current flow as the loads ?
where is the need for short circuit test for 3 see is required and why? can you explain in brief with application
What is VCB? where it is installed at SP. What is SP?
For RCD (Residual current device) Icu is defined. How i can find Ics for them?
What is the Surge for 1.1 Phase Induction Motor(For Eg.1Hp) 2.3 Phase Induction Motor(For Eg.1Hp) 3.AirConditioner(For Eg 1Ton) 4.Refrigerator(For Eg 180Ltr or 160kW) 5.Induction Cooker 4. Ceiling Fan