Answer Posted / guest
ac moter will not run because AC moter need to run flux
& in DC FLUX Not genratetd
| Is This Answer Correct ? | 1 Yes | 1 No |
Post New Answer View All Answers
why do we need to use 3c+3e cable, normally i select only 3c+e cable and i think it is enough. pls explain the usefull of 3e cable ( in this project the earthing system is well done)
what is allowable ac mixing in dc
What is effect of harmonic current (Draw by VFD) on power system/ electrical Equipments ?
it is possible to measurement of tension of slipring induction motor(SRIM)carbon brushes, any maesuring instruments are available in the markets.
What is PQA???Applications........
what is sustainable current of any conductors . a bare busbar or pvc cable has different sustainable current .
what is reactive power?, why its measured in VA ? is it transient behavior of system?
Dear all, I just want to ask an expert on this forum for some insights. For the magnetic balance test, when applied voltage on a Delta-Star transformer e.g. Dyn11, the following relationships apply for HV side: 1. H1-H2 = H2-H3 H3-H1 2. H2-H3 = H3-H1 H1-H2 3. H3-H1 = H1-H2 H2-H3 For the LV side also: 4. X1-X0 = X2-X0 X3-X0 5. X2-X0 = X3-X0 X1-X0 6. X3-X0 = X1-X0 X2-X0 Is there a similar pattern for Y-d, Y-Y, D-d? And how about Y-z, D-z, Z-y transformers? I've tested a YNzn5 transformer and for LV side I don't see the pattern. In this particular case I got for LV side the following (see values below): H1-H0 H2-H0 H3-H0 X0-X1 X0-X2 X0-X3 128.0 119.9 7.2 29.2 13.3 15.8 70.7 128.4 59.2 23.4 22.0 3.6 7.2 120.1 128.1 13.4 29.3 15.8 What is the relationship here for LV? For row 1 I see the relationship, for row 3 I also see but it's shifted, but for row 2 I don't see such relationship. Any suggestions, answers, someone?
actually i can't understand what is 3dB ? and it's really not clear to me.please any one let it me be cleared.
what is negative and zero impedance in 3 phase induction motor ??
what is the use of vcb & isolator in substation?
We have 750KVA DG set, we want to introduce REF relay with 1250/1A,CL PS,Current transformers.The lead distance of 2.5mm copper flexible cable from CT to relay is around 5mtrs.We would like to know the knee point votage(VK) & IM calculion for CT's
at what base you will tell the direction of rotation of dc motors and generators?
is it possible for different brand of H.V transformers to run or operate in parallel to each other? if so how much disturbance can this affact the H.V bus bar?
How a capacitor discharge weld power supply works? what is the use of a pulse transformer?