What is pipe schedule?
What are all effects its having in the valve?
how do we take care of pipe sch in case if the customer dint
specify in the data sheet.
What we need assume and in what basis?
Answer Posted / shankar
Thickness of the pipe is normally spelled in Schedule
example 1/2" Sch 40S,
Generally, ID (Inside diameter) of the pipe will vary by
varying the thickness but OD (Outside Diameter) remains
constant. But it is vice versa when we speak about tube,
where ID remains onstant and OD will change by varying
thichmess.
For a valve with welded end connection ,schedule of the
valve is needed, so that while joining valve with the pipe,
both ID of valve and pipe shall be matched. For that most
of cases schedule is important.
In case when pipe sch is not given, we have to follow ASME
31.3 code to find the required thickness for the design
pressure and temperature.
| Is This Answer Correct ? | 4 Yes | 1 No |
Post New Answer View All Answers
what can of fault ofently come in vibration mesurement?
What is force balance principle? State some of its’ advantages.
What is the advantage of using locally fabricated hook ups over Pre fabricated hook ups in process instrumentation?
What are different types of valves?
IN CONTROL VALVE SPECIFICATIONS GENERALLY TERM " DE- 200" ."DM -400"USED,, WHAT IS DE/ DM STANDS FOR?
Can anybody please let me know Orifice plate sizing calculation formula and step by step procedure
it is possible to check the fail safe condition in pressure transmitter. if possible how?
What is three element in drum level?
How to do gas analysers calibration in AUTO and Manually by using zero and span gas?
Specify eight technical requirements that you would consider important, when deciding upon a particular control valve?
Working principle of magnetic flow meter ......and calibration procedure of e+h magnetic flowmeter...
Explain the working of an electronic level troll.
Explain the mechanism behind the turbine meter.
Can I calibrate the Electromagnetic Flow Meter on line and How.
how does we calibrate a square root flow transmitter ,give an example and explain it step by step like range calculation , calibration hook up series connection , zero check , and how to apply pressure , and if not geting proportional output then what should we do ?