what is difference between HART communication and BRAIN
communication?

Answer Posted / samir & manoj

BRAIN its specially designed for YOKOGAWA instruments, By
it you can only communicate with YOKOGAWA instruments, HART
is universal protocol, it can communicate with mostly
brands of instruments. As HART having multiple licence with
many downloaded softwares.

Is This Answer Correct ?    38 Yes 8 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

how to relay switch sense the fault?

2093


WHAT IS THE DIFF. BETWEEN SKIN TEMPERATURE AND PASSES TEMPERATURE..?

2088


What is surge and how is it prevented, what is the purpose of bypass valve across AS valve.

1481


Difference between dcs and plc including date processing and architecture.

625


I want to know about DDCMIS in detail ? please explain it. Also give name of reference books in which it is explained in detail in very simple manner.

3308






We Have Two Field bus Pressure Transmitters of Different Sensor Range (I.E One is of Lower range and Another is of Higher Range).Is same Process Line. My Question is Can i provide Saturation Limit to my field Bus Transmitter as We can provide Saturation current limit to HART Instruments. As During Low Pressure Both Working OK ,But During High Pressure, transmitter with Lower sensor range Goes to Fault mode as Beyond its Sensor Limit it can Measure, So may I provide Saturation point Some where to Suppress This Fault during High Pressure.

1146


How to find out the current of two motors having same power consumption but different RPM?

1547


Linear amplifier.

1548


what is the calibration procedure for transweigh make weigh feeder?

3466


Using your own examples solve a problem involving normal table. (experimental method and analysis)

686


HI, can anybody give details about GAS TREATMENT PLANT CONSTRUCTION,as INSTRUMENTATION ENGINEER what are the responsibilites.what are the instruments mainly instrumentation engineer will deal with

1621


while i check zero check for dp flow transmitter some fluctuating came (0 to 458 kg/h) what is the reason?

1351


How do bending tubing provide better measurement than using tubing fittings such as elbows?

1488


what step is taken for ESD ( emergency shut down) in DCS REPLY to hashimka20009@gmail.com

1895


installation process of orifice,a question asked for confusion creation in interview by BARC 1.if orifice is tightly fitted with pipe ,it will act like venturi 2.if orifice is left hanging in between liquid it will not create the pressure difference exactly,

1674