Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is difference between 3 wire and 4 wire RTD sensor?

Answer Posted / imran aslam

3rd wire is used as compension and if we use 4 wire RTD it
elemeneted more resistence as compere to 3 wire.4 wire is
more perfect

Is This Answer Correct ?    41 Yes 4 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

Why we are using DPT(Differential Pressure Transmitter) in separator instead of level trasmitter?

2275


Senior engineer's please help me, what is Loop Checking and Loop test? and write difference also? soon urgent

2096


We Have Two Field bus Pressure Transmitters of Different Sensor Range (I.E One is of Lower range and Another is of Higher Range).Is same Process Line. My Question is Can i provide Saturation Limit to my field Bus Transmitter as We can provide Saturation current limit to HART Instruments. As During Low Pressure Both Working OK ,But During High Pressure, transmitter with Lower sensor range Goes to Fault mode as Beyond its Sensor Limit it can Measure, So may I provide Saturation point Some where to Suppress This Fault during High Pressure.

1648


For what reason would you possibly be compelled to make use of a Smith Predictor. Explain the idea behind the operation of this device.

1916


give eg of how I/P is used in control loops

1935


What is Positive Calibration and Negative Calibration?

2242


pls suggest suitable MOC of diaphragm for pressure measurement of UREA grade solution service fluid.

3121


how to check earthing,what is minum ohms for proper earthing

1938


why we take %i0.0 as input for twido plc

2164


please send me some question papers of HPCL aptitude test ?? please send it to bipinb.28@gmail.com ...

1969


what is cold loop? difference between hot and cold loop?

2234


Explain why use mmwc unit?

1037


TEMPERATURE VARIATION FOR FREQUENTLY.

2041


Area classification, Equipments, Gas groups, temperature classification, Ingress protection, Fire Extinguishers.

1979


Why does a pressure gauge installed on reactor, doesn't have any vent line below to release the pressure? Is it any kind of designing mistake or it actually does not require any vent line? And if it does not require any vent line below it then how we are gonna release the pressure built inside the pressure gauge?

2168