What do you mean by deregulated power system structure?
Which structure (regulated/deregulated) is used by modern
power system?
Answer Posted / iamdon
Deregulated power system structures means all major tasks
(Generation,Transmission and Distribution)are
unbundled.Deregultaion has paved the ways for private
players to emerge and also it bring competitivness amoung
the existing companies.
Generation is done by Generation companies(GENCOs).e.g,
NTPC,NHPC,DVC,NPCIL,Tata Power etc.
Transmission is done by Transmission companies
(TRANSCOs).e.g, PGCIL
Distrisution is done by Ditribution companies(DISCOs).e.g,
State electricity boards.
Now a days we are using deregulated structure of power
system.In earlier days we were using regulated structure
where all tasks were performed by same utilitty
companies.Clearly we can see that the regulated structure
of power system was not efficient and effective thats why
we switched to deregulated PS structure.
Author:arbelectbit@yahoo.com
| Is This Answer Correct ? | 24 Yes | 4 No |
Post New Answer View All Answers
WHY IL=IPH IN STAR AND WHY IPH=IL/1.732 IN DELTA? WHAT IS REASON BEHIND IT?
why occ characteristics of generator is also called as magnatization characteristics ?
what topics we have to concentrate for power grid et.written test.and tell what to read for english synonyms and antonyms.
what questions are asked in the interview for the post of an electrical maintenance engineer in FMCG companies?
what is the difference between changer, converter and transformer?
Why let through energy not considered for ACB breaker while cable sizing?
What are the advantages of skewing of cage rotor conductors?
Dear sir, How to calculate 3.5 core pvc aluminium armoured cable meter wise carrying amps rating.Please give the solution with a good example.
Distribution transformer we provided 2 separate earthing pit for Body and 2 separate earthing pit for neutral,we can not connect separate body earthing pit to other earthing pit but we do metal glanding in secondary side cable termination in both side, transformer and PCC panel (LT Panel), is this safe for transformer and other equipment?
What is the criteria that generally follow by distribution licenses to fix contact demand of their industrial customers?
How to calculat the ratio of HT\LT in energy meter
How we can defined theecopper cable size if we know the aluminium cable size?
why using transformer and thyristor switch in 3 phase apfc panel
After taking shutdown of 11kv feeder, if you see 5kv by phasing stick in the cable side, is it possible to close earth switch in cable.
What is power distribution criteria for converting single phase unbalanced residential load to 3 phase star connected balance system. Does total KW converted to 3 Phase. Means Divided by root 3.