Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the purpose of taking Capacitance and Tan Delta
Test in
Transformer bushing?

Answer Posted / dinesh lokhande

Transformer bushings OIP (Oil impregnated paper) consist of
paper foil surrounig conductor which termiantes at test tap
and oil is filled in between paper. This arrangement is
equivlent to no of capacitances in series.

To check healthiness of deielectric we conduct Capacitance
Tan detla test from specially designed apparatus which
gives values of capacitance and tan delta which can be
compared to Factory test results and designed values.

Vector disagram is as shown below.

Ia* *Ic
* *
* *
*D *
* *
**
*************** V

In above vector we can explian as follows.
From property of ideal capacitor currnet vector Ia leads
Voltage vector V by 90 deg.

However due to dielctric losses, Calculated or charging
current Ic lags behind actual current by angle delta (D -
dielctric loss angle).

Hence Tan delta calculated is dielectric loss.

Is This Answer Correct ?    22 Yes 5 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

How to distinguish whether MCB is DC or AC looking at it physically

1968


Why we are using only Dyn11 tranformer in distribution system but not using a Dyn1 in distributing system?why not and advantage and disadvantage in both

2721


In power transmission using open belts or horizontal shafts it is preferable to have the slack side of the belt on the top because

1219


how to select correct size of power cable for inverter duty motor

1571


When we giving the 3 phase supply to ups system how to coming netural?

2104


How can ou verify the size of conductor 50Sq.mm ACSR

1930


WHAT IS THE TOTAL POWER GENERATION IN CHHATTISGARH?

1960


I Need standard operation procedure(SOP)for 500kva Oil type transformer oil filtration & Procedure for IR value checking.

2886


At what speed an electric car can run with 2 HP motor of weighing 400 kg?

1812


What are the advantages of instrument transformer?

1155


what is settable hystersis protection? If any body knows plz kindly post the answer..

2044


What happened ,If 3 phase clearance not maintained in 33KV Line,11KV LIne etc?

2351


What is difference between start imitation and start interlock for 3 phase motor protection ?

2247


33kv Rated output avilable in market (any where in india)

2074


How you give clearance to a spare feeder.

1690