what r the earthing required for commissioning of D.G set?
Answer Posted / skumar
Total four earthing are required for DGs. two No of earthing
for body (i.e Pipe earthing). Another two no of earthing for
Neutral earthing(i.e Copper plate earthing).Both the
earthing are more importance for DG commissioning
| Is This Answer Correct ? | 12 Yes | 0 No |
Post New Answer View All Answers
hello friends this is krunal here.. i have applied for he officer train in hpcl electrical stream.. any one who have applied before for electrical stream please help me out.. post ur reply to my mail id: krunal_airforce@yahoo.com.. any tips, old questions for paper or any help will do.. plz help me.. your faithfully, Krunal Darji
What kind of socket shall be provided for window type air conditioner with cooling capacity upto 18000 BTU/hr
Explain the role of a car driver as one of a feedback mechanism.
Why you are switching off arc protection mcb when you are taking shutdown for lv board.
May I know how much values to be set for earth fault, over current and short circuit values at 11kv side? I have 11kv van 1250amps rating. Present it's taking load 80amps?
234 MVA Generator 3 phase Short circuit current Values required? Gen set Rating-234 MVA, Gen Voltage-18kv, PF;0.8, Xdv:23.5 %, Transformer Rating-18/380KV, 680MVA,Yndd1 two winding, Step up TR, ZT:35.50 %,X/R 4.33 Gen CB Position, CB open ,Disconnected open, Generator Running Voltage 18 Kv, Bi mistakes generator side earth switch Closed during that time short circuit current level in 3 Phase required, and how to test on site 234MVA Generator Short circuit current,
why magnet has north and south poles only why not east and west and why we are considering as north and south poles? why cant we consider as east and west?
which network topology offers the greatest level of tolerance?
Differentiate between digital phase converter and ordinary phase converter.
if there are six generators (3 gas CATT, one Jenbacher o1 MW each, and two nos Diesel 01 no 01 mw other 0.65mw EDGs ( say), 3 CAtt gas set have identical pole pitch,01mw EDG and Jenbacher gas Set have different pole pitch, how their power connection can be done to connect a common bus bar during installation. in short, how different pole pitched generators power connection can be done to connect a common busbar system through generators incomer ACBs.
How to decide the size of the capacitor for a single phase induction motor say 2 HP ??
we use capister for power factor. when we use capaciter in dg circuit than defect dg. can we use capaciter bank for dg circuit
why they were using TRIAC instead relay in some controllers and what is the advantages.
what happen if drive input fail momentry at 48.5 HZ frequency?
I have an existing old MCCB. ABB Model SACE, the rating are: Ue = 660 volts, Iu =1250 Amps, 3 poles, Ith (max) =800 amps at 45 deg C. I need a circuit breaker for my 3 phase motors, 380 volts 60 hz. the supplier required the minimum ampacity of the breaker to be 911 amps. can i use this breaker with rating of Iu =1250 amps but Ith = 800amps maximum?