Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

How check electrical motor winding.

Answer Posted / manish kumar

1. Check the resistance of all windings. In case of three
phase motors resistance of all windings should be same.

2. Check the insulation resistance with megger. It should be
near about 1M-Ohm.

Is This Answer Correct ?    11 Yes 1 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

In Electrical 'Single Line Diagram' cable nomenclature shows "2 X 1C X 630sq.mm to be provided for one incomer. The question is how many cable to be proved for one Incomer.

1750


What is miller crystal oscillator? Explain its operation?

1104


Dyn1 transformer vector group testing how to do

1794


how to operate and maintenance of 1500 kva diesel generator set

1805


Why you are switching off arc protection mcb when you are taking shutdown for lv board.

1692


why HT armoured cable does not glanding

4227


list of tests to be carried out at manufacturers end while purchasing a step up transformer of 11kv to 66kv ,2MVa Capacity.

1977


Please brief what is sinewave

2142


how to calculate current carring capacity of cable and cable selection? 1) copper flexible cable 2) copper armoured cable 3) Aluminium cable

1603


A Question Like A Wire Is Wound Whose Resistance Is Some 132. 44647 Ohms. If A Voltage Of 30 mv, 296 Ma Current Is Applied To It What Is The Resistance.

1058


Is it true online ups having bypass mode if it is true then why we called ups because it is interrupting power when goes in bypass mode

2019


what is formula to cal cute earth pit numbers and size of earth strip used in earthing?

2211


Can double compression glands be used with regular cables?

2097


WHTA IS LIMT OF LEAKGE CURRENT OF 11 KV 1 CORE 1000SQ.MM. XLPE CABLE.LOAD ON CABLE IS AROUND 600AMP .LENGTH 500 MTRS.

2138


how define the torque in ac drive. from electrical side in the drive friquency ,voltage and current three factor is there.

2219