Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the working principle of ceiling fan?

Answer Posted / nilesh vyas

The celing fan motor works on principle of single phase
induction motor using capacitor.
Working of capacitor start motor: The stator consists of
the main winding and a starting winding (auxiliary). The
starting winding is connected in parallel with the main
winding and is placed physically at right angles to it. A
90-degree electrical phase difference between the two
windings is obtained by connecting the auxiliary winding in
series with a capacitor and starting switch. When the motor
is first energized, the starting switch is closed. This
places the capacitor in series with the auxiliary winding.
The capacitor is of such value that the auxiliary circuit
is effectively a resistive-capacitive circuit (referred to
as capacitive reactance and expressed as XC). In this
circuit the current leads the line voltage by about 45°
(because XC about equals R). The main winding has enough
resistance-inductance (referred to as inductive reactance
and expressed as XL) to cause the current to lag the line
voltage by about 45° (because XL about equals R). The
currents in each winding are therefore 90° out of phase -
so are the magnetic fields that are generated. The effect
is that the two windings act like a two-phase stator and
produce the rotating field required to start the motor.
When nearly full speed is obtained, a centrifugal device
(the starting switch) cuts out the starting winding. The
motor then runs as a plain single-phase induction motor.
Since the auxiliary winding is only a light winding, the
motor does not develop sufficient torque to start heavy
loads. Split-phase motors, therefore, come only in small
sizes.

Is This Answer Correct ?    400 Yes 62 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

formula for calculation of switchgears(i.e. contactor, fuse, cb, relay etc.), if load current is given?

2274


List the characteristics of filter?

1114


What are steps to be taken while designing of DYN11 distribution transformer to achieve magnetising balance?

3583


What fomula is used to calculate: 1. rated frequency withstand voltage, and 2. rated lightning impulse withstand voltage.

1771


is it necessary to earth the rmu before cutting off the transformer winding?if yes why?

1982


What is the diff. between single compression and double compression gland

2052


how to calculate cable size in diffrent loads?

2131


What is the function of electron gun assembly used in crt?

1240


What is distance between electrical panel to land ?

1639


why ten delta testing is carried out on power transformer

1862


At what speed an electric car can run with 2 HP motor of weighing 400 kg?

1880


What is mean 2XWY

2550


in ring main system we use the isolater b/w transfer bus and main bus if we r not use isolatar than wat will be the effect in our sys.

2146


what is the working process of over & under voltage relay.

2288


Why auxiliary transformers are not connected in parallel in primary stations?

1467