Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

What is the working principle of ceiling fan?

Answer Posted / nilesh vyas

The celing fan motor works on principle of single phase
induction motor using capacitor.
Working of capacitor start motor: The stator consists of
the main winding and a starting winding (auxiliary). The
starting winding is connected in parallel with the main
winding and is placed physically at right angles to it. A
90-degree electrical phase difference between the two
windings is obtained by connecting the auxiliary winding in
series with a capacitor and starting switch. When the motor
is first energized, the starting switch is closed. This
places the capacitor in series with the auxiliary winding.
The capacitor is of such value that the auxiliary circuit
is effectively a resistive-capacitive circuit (referred to
as capacitive reactance and expressed as XC). In this
circuit the current leads the line voltage by about 45°
(because XC about equals R). The main winding has enough
resistance-inductance (referred to as inductive reactance
and expressed as XL) to cause the current to lag the line
voltage by about 45° (because XL about equals R). The
currents in each winding are therefore 90° out of phase -
so are the magnetic fields that are generated. The effect
is that the two windings act like a two-phase stator and
produce the rotating field required to start the motor.
When nearly full speed is obtained, a centrifugal device
(the starting switch) cuts out the starting winding. The
motor then runs as a plain single-phase induction motor.
Since the auxiliary winding is only a light winding, the
motor does not develop sufficient torque to start heavy
loads. Split-phase motors, therefore, come only in small
sizes.

Is This Answer Correct ?    400 Yes 62 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

can any one suggest paper presentation topies for electrical engg?

1999


how to CHECK CT AND PT AT THE FAULT OCCUR IN GENERATOR RELAY PANEL .

2282


Define gain margin?

1189


how to prepare the technical test

2091


gas turbine genrator reactances

2000


how to calculate slip ring induction motor stator and rotor currents??

2264


Generation of voltage for each phase are same of a turbogenerator.Although the short circuit current flow when two phase of turbogenerator are shorted(where current can't flow without potential difference),why?

2123


Actuality I have at home electrical panel with 220v 50hz, and I want to converter from there to 110v 60hz, to wiring on the half of my house. Also I like to keep another half of my house with the original 220v 50hz. What is the best and safety way to do?

1817


sir i completed apprentice in TNEB.apprentice is eligible for 'c' licence

2166


What is the Good Earth resistance value of G.I & Cu. Chemical Earthing & Normal Pipe Earthing?

2345


IF TVM OF TRANSFORMER SHOWS POWER FACTOR ON 33 KV SIDE AS 0.97 LAGGING AND ON 132 KV SIDE IS 0.75 LEADING.IS THIS CORRECT.WHERE IS PROBLEM.

2368


how to determine the cable size...pls explain me with the formula taking particular load....does the factors like impedance & short circuit rating influence the cable size, if so how....

2057


Explain the role of a car driver as one of a feedback mechanism.

1190


What is the temperature PROFILE OF A FLUID W. R. T. Distance from a sphere to which it is IN CONTACT which is at constant temp.?

2064


What is a DC series motor?

1239