Golgappa.net | Golgappa.org | BagIndia.net | BodyIndia.Com | CabIndia.net | CarsBikes.net | CarsBikes.org | CashIndia.net | ConsumerIndia.net | CookingIndia.net | DataIndia.net | DealIndia.net | EmailIndia.net | FirstTablet.com | FirstTourist.com | ForsaleIndia.net | IndiaBody.Com | IndiaCab.net | IndiaCash.net | IndiaModel.net | KidForum.net | OfficeIndia.net | PaysIndia.com | RestaurantIndia.net | RestaurantsIndia.net | SaleForum.net | SellForum.net | SoldIndia.com | StarIndia.net | TomatoCab.com | TomatoCabs.com | TownIndia.com
Interested to Buy Any Domain ? << Click Here >> for more details...

what is electricial and mechnical interlock.

Answer Posted / anwar

hai iam anwar

Electrical Interlock :
this interlock is possible only when any
supply is possible by using one shunt trip & Auxiliary
Contact for any two incomers.if two supply EB & DG in normal
condition only normal incomer supply is in on condition.when
Normal supply is cut then dg supply incomer is comes to on
condition so when suddenly Normal supply is come then only
supply available in one incomer other incomer will on the
OFF position itself by using of shunt trip.


Mechanical Interlocking :
this interlock is used by manually
using the castell lock.

Is This Answer Correct ?    25 Yes 6 No



Post New Answer       View All Answers


Please Help Members By Posting Answers For Below Questions

When distance between two pulleys is not fixed, the tension of belt is adjusted by a) driver shaft b) driven shaft c) adjustment screw d) belt

2973


How may I get the maximum current capacity for a particullar size Alluminum or Copper cable if there is compulsion to use?

1857


what is cogging and crawling

2462


High voltage test procedure of in swgr board. why should measure millivolt drop on testing time?

2043


An 8 pole, 50 Hz, 3-phase IM is loaded to a poing where pull out torque will occur. The rotor resistance per phase is 0.3 ohm and motor stalls at 650 rpm. The rotor reactance at stand still is A 2 ohm B 1.25 ohm C 3.15 ohm D 2.25 ohm

2211


A generating system will have a total capacity of 300 MW. Find the probable forced outage when the capacity is supplied by two 150 MW units. The operating probability of all units is P=0.98 and forced outage probability rate Q =0.02 .

2580


What the difference between three phase contactor (coil 110vac) & three phase SSR (control voltage 110Vac)? May I use contactor in place of SSR?

2111


In case of generator when we consume more power produces by it why load on generator increase and starts sound more. and how it is adjusted..

1895


If any cable burnt how can we identify it burnt by high current of high voltage? 

2398


The capacitive reactance of a capacitor of 1/(2(PI)) F at 10^3 H is

1789


In dc ckt. 24v or 110v, which one is more efficient and why?

2180


in india per day how much power is generated including all power station

1885


What is the efficiency during maximum power transfer?

1156


How to calculate the fuel consumption for 600kva DG genset which connecting with 25%load?

2076


IF 8255 CONTROL WORD IS 94H,Tell the chip port work mode ?

2524